NPort 5600 Series User’s Manual

Configuring NPort Administrator

Serial Parameters

ATTENTION

Check the serial communication parameters in your Serial Device’s user’s manual. You should set up NPort’s serial parameters with the same communication parameters used by your serial devices.

Baudrate

Setting

Factory Default

Necessity

50 bps to921.6 Kbps

115.2 Kbps

Required

Data bits

 

 

Setting

Factory Default

Necessity

5, 6, 7, 8

8

Required

 

 

 

When the user sets Data bits to 5 bits, the stop bits setting will automatically change to 1.5 bits.

Stop bits

Setting

Factory Default

Necessity

1, 1.5, 2

1

Required

 

 

 

Stop bits will be set to 1.5 when Data bits is

set to 5 bits.

 

Parity

 

 

Setting

Factory Default

Necessity

None, Even, Odd, Space, Mark

None

Required

 

 

 

Flow control

 

 

Setting

Factory Default

Necessity

None, RTS/CTS, DTR/DSR, Xon/Xoff

RTS/CTS

Required

 

 

 

FIFO

 

 

Setting

Factory Default

Necessity

Enable, Disable

Enable

Required

 

 

 

NPort’s serial ports provide a 16-byte FIFO both in the Tx and Rx directions. Disable the FIFO setting when your serial device does not have a FIFO to prevent data loss during communication.

Interface

Setting

Factory Default

Necessity

NPort 5610-16/8: RS-232 only

RS-232 only

Required

NPort 5630-16/8: RS-422/485 only

4-wire RS-485

Required

 

 

 

NPort 5650-16/8

RS-232

Required

 

 

 

5-10

Page 40
Image 40
Moxa Technologies NPort 5600 user manual Serial Parameters