NPort 5600 Series User’s Manual

Configuring NPort Administrator

UDP Mode

Packing length

Setting

Factory Default

Necessity

0 to 1024

0

Required

 

 

 

Default = 0, The Delimiter Process will be followed, regardless of the length of the data packet. If the data length (in bytes) matches the configured value, the data will be forced out. The data length can be configured for 0 to 1024 bytes. Set to 0 if you do not need to limit the length.

Delimiter 1

Setting

Factory Default

Necessity

00 to FF

None

Optional

 

 

 

Delimiter 2

 

 

Setting

Factory Default

Necessity

00 to FF

None

Optional

 

 

 

Once the NPort receives both delimiters through its serial port, it immediately packs all data currently in its buffer and sends it to the NPort’s Ethernet port.

Delimiter process

 

Setting

 

Factory Default

 

Necessity

 

Do nothing, Delimiter + 1, Delimiter +

 

Do Nothing

 

Required

 

2, Strip Delimiter

 

 

 

 

 

 

 

When [Delimiter + 1] or [Delimiter + 2] is selected, the data will be transmitted when an additional byte (for Delimiter +1), or an additional 2 bytes (for Delimiter +2) of data is received after receiving the Delimiter.

When [Strip Delimiter] is selected, when the Delimiter is received, the Delimiter is deleted (i.e., stripped), and the remaining data is transmitted.

When [Do nothing] is selected, the data will be transmitted when the Delimiter is received.