Moxa Technologies NPort 5600 user manual Pair Connection Slave Mode, Blank

Models: NPort 5600

1 119
Download 119 pages 1.96 Kb
Page 56
Image 56

NPort 5600 Series User’s Manual

Configuring NPort Administrator

 

Destination IP address

 

 

 

 

Setting

Factory Default

Necessity

 

 

IP address or Domain Name

blank

Optional

 

 

(E.g., 192.168.1.1)

 

 

 

 

TCP port No.

4001

Required

 

The Pair Connection “Master” will contact the network host that has this IP address. Data will be transmitted through the port No. (4001 by default). Note that you must configure the same TCP port No. for the device server acting as the Pair Connection “Slave.”

Pair Connection Slave Mode

When using Pair Connection Mode, you must select Pair Connection Slave Mode for the Operation mode of one of the NPort 5600 device servers. In effect, this NPort 5600 will be acting as a TCP server.

TCP alive check time

Setting

Factory Default

Necessity

0 to 99 min

7 min

Required

 

 

 

0 min: TCP connection is not closed due to an idle TCP connection.

1 to 99 min: NPort 5600 closes the TCP connection automatically if there is no TCP activity for the given time.

Local TCP port

Setting

Factory Default

Necessity

TCP port No. (e.g., 4001)

4001

Required

This Port No. must be the same port No. that you set up for the Pair Connection “Master” device server.

5-26

Page 56
Image 56
Moxa Technologies NPort 5600 user manual Pair Connection Slave Mode, Blank