Moxa Technologies NPort 5600 user manual Event Type, Snmp Trap Server

Models: NPort 5600

1 119
Download 119 pages 1.96 Kb
Page 64
Image 64

NPort 5600 Series User’s ManualConfiguring NPort Administrator

SNMP Trap Server

SNMP trap server IP or domain name

Setting

Factory Default

Necessity

IP or Domain Name

None

Optional

 

 

 

Event Type

Cold start

This refers to starting the system from power off (contrast this with warm start). When performing a cold start, NPort will automatically issue an Auto warning message by e-mail, or send an SNMP trap after booting up.

Warm start

This refers to restarting the computer without turning the power off. When performing a warm start, NPort will automatically send an e-mail, or send an SNMP trap after rebooting.

Authentication failure

The user inputs a wrong password from the Console or Administrator. When authentication failure occurs, NPort will immediately send an e-mail or send an SNMP trap.

IP address changed

The user has changed NPort’s IP address. When the IP address changes, NPort will send an e-mail with the new IP address before NPort reboots. If the NPort is unable to send an e-mail message to the mail server within 15 seconds, NPort will reboot anyway, and abort the e-mail auto warning.

Password changed

The user has changed NPort’s password. When the password changes, NPort will send an e-mail with the password change notice before NPort reboots. If the NPort is unable to send an e-mail message to the mail server within 15 seconds, NPort will reboot anyway, and abort the e-mail auto warning.

5-34

Page 64
Image 64
Moxa Technologies NPort 5600 user manual Event Type, Snmp Trap Server