Manuals
/
MTD
/
Kitchen Appliance
/
Ventilation Hood
MTD
ERV 365 manual MTD-ERV 350, Installation Operating Manual
Models:
ERV 350
ERV 365
1
1
56
56
Download
56 pages
39.4 Kb
1
2
3
4
5
6
7
8
<
>
Install
Wiring Diagram MTD-ERV 350 - LEFT-HAND Standard Version
For replacement
Warranty
Dimension
Malfunctions or Problems without Indications
CAUTION Reset unit
Default
Time delay values
ReadingandSettingComfortTemperature
Page 1
Image 1
™
MTD-ERV
350 / 365
Installation &
Operating Manual
Page 2
Page 1
Image 1
Page 2
Contents
MTD-ERV 350
Installation Operating Manual
All rights reserved
Table of Contents
Wiring Diagram MTD-ERV 350 - LEFT-HAND Standard Version
1.3 Warranty and Liability
1.2 CE Symbol
The warranty will be voided if
1.3.2 Warranty Terms
1.4.1 Safety Precautions
1.4 Safety
1.4.2 SafetyInstallationsandSafetyMeasures
1.4.3 Symbols Used
2. Instructions for the User
2.1.2 Heat Recovery
2.1 Definition of Terms
2.1.1 Balanced Ventilation
2.2 Available Operating Aids
2.1.6 Moisture Recovery Option
2.2.1 CC Ease Operating Unit
4 Instructions for the User
2.2.2 3-position Switch Option
Reading off the comfort temperature
2.3.1 Setting Date and Time
2.2.3 Bathroom Switch Option
2.3.2 ReadingandSettingComfortTemperature
2.3.3 ReadingandSettingVentilationLevel
Setting the comfort temperature
Setting the ventilation level
Reading off the ventilation level
2.3.5 SwitchingSupplyandExhaustAirFansOn and Off
2.3.4 Switching Extractor Hood On and Off Option
This functions only with ventilation set to AUTO
2.3.6 Setting Ventilation Programme
Weekday fan position Weekend fan position
Making settings in the P menus
Access to the P menus
2.3.7 Setting Additional Functions via the P Menus
Return to the main window
Default
Menu P2 ! Set time delays
setting
Menu P1 ! Status of the functions
Menu P9 ! Status of the functions from menu P5
Time delay values
Default
setting
2.5 Service by the User
2.4 Use of the Switches Option
2.4.1 Setting Ventilation Using 3-position Switches
2.4.2 Setting Ventilation Using Bathroom Switches
For replacement
For cleaning
2.5.1 Cleaning or Replacing Filters
2.6.2 3-positionSwitchwithMalfunctionLED
2.5.2 Cleaning Valves in the Home
On the position of the valves
2.6 Malfunctions
2.6.3 What to Do in the Event of a Malfunction?
2.7 End of Service Life
16 Instructions for the User
3.1 Components of the Balanced Ventilation System
3 Function of the System
3.2 Controlled Ventilation System
E F B
3.3 MTD-ERV
3.4. Additional Options
MTD-ERV 350 Methods of Operation
3.4.1. Preheater in MTD-ERV
3.4.3 Post-heater* in Duct System
3.4.2. Ventilation via Extractor Hood
3.4.5. RH Sensor* in the Home
3.4.4 CO2 Sensor* in the Home
3.4.7 Chimney Sweep Control
3.4.6 Underground Geothermal Heat Exchanger
22 Function of the System
MTD-ERV 350 nL normal Air Volume
3.5. Technical Specifications
Position
Ventilation rate
24 Function of the System
Function of the System
3.6 Dimension Sketch
4.1 Preconditions for Installation
4 Instructions for the Installer
4.2 Installation of the MTD-ERV
4.2.1 Transport and Unpacking
4.3.1 Connection of the Air Ducts
4.3 Wall Mounting
4.3.2 Connection of the Condensation Drain
LEFT
Access to the P menus
4.4 Commissioning the MTD-ERV
MTD-ERV 350 RIGHT
Menu
Return to the main window
Making settings in the P menus
to set several parameters in turn in
once
Menu P3 ! Set ventilation controls
Menu P4 ! Read off the temperatures % and ppm
30 Instructions for the Installer
Menu P5 ! Setting additional control functions
Menu P7 ! Read off malfunctions and system information
Menu P6 Setting additional control functions
Values for additional control functions
Minimum
Max Min
Menu P8 Open-loop and closed-loop control
4.6 Maintenance by the Installer
4.5 Setting the Air Specifications
4.6.1 Inspection of Heat Exchanger and Fans
MTD-ERV 350 - R
MTD-ERV 350 - L
36 Instructions for the Installer
4.6.2 Filter Cleaning, if Preheater is Fitted
4.7.1 Malfunction Indications on the CC Ease Display
4.7 Malfunctions
38 Instructions for the Installer
4.7.2 Malfunction indications on the CC Ease Display à Remedy
CAUTION Reset unit
CAUTION Reset unit
Reset unit
Reset unit
Instructions for the Installer
E A1
CAUTION Reset unit
40 Instructions for the Installer
CAUTION Reset unit
CAUTION! Avoid contact with the PCB and frost protection
CAUTION! Avoid contact with the PCB and frost protection
Instructions for the Installer
element due to risk of electrocution
CAUTION! Avoid contact with the PCB and frost protection
A0 / A10 / A11
42 Instructions for the Installer
If the fuse is OK, the circuit board is defec
4.7.3 Malfunctions or Problems without Indications
Voltage only on N & L3 & L1 or N & L3 & L2
Number Part
4.8 Spare Parts
Supply air
4.9 Wiring Diagram MTD-ERV 350 - LEFT-HAND Standard Version
Exhaust air
Instructions for the Installer
46 Instructions for the Installer
4.10 Wiring Diagram MTD-ERV 350 - LEFT-HAND Luxury Version
Supply air M
M Exhaust air
Instructions for the Installer
4.11 Wiring Diagram MTD-ERV 350 - RIGHT-HAND Standard Version
Exhaust air
Supply air
48 Instructions for the Installer
4.12 Wiring Diagram MTD-ERV 350 - RIGHT-HAND Luxury Version
Exhaust air M
M Supply air
EC Declaration of Conformity
4.13 EC Declaration of Conformity
Page
Page
Unit 1, Burgage Business Park, Blessington, Co. Wicklow, Ireland
Tel +353 045 900 590 Fax +353 045 900 Email info@mtd-solutions.com