2.5.1 Cleaning or Replacing Filters

2

2.5.1 Cleaning or Replacing Filters

As soon as the corresponding warning appears on the display of the CC Ease operating unit, the filters have to be cleaned or replaced.

“ FILTER I ! The internal filters must be cleaned or replaced.

“ FILTER E ! The external filters* must be cleaned or replaced.

One of the filter indications shown above then ap- pears on the CC Ease display.

For cleaning ... The internal filters are supplied as stand- ard with the MTD-ERV 350. The external filters* form part of the duct system of the ventilation system and do not belong to the MTD-ERV 350.

The MTD-ERV 350 is equipped as standard with two internal filters. The external filters* form part of the duct system of the ventilation system and do not belong to the MTD-ERV 350. Should your ventilation system be equipped with external fil- ters, the monitoring of these filters must be con- nected to the PCB panel (extended version) of the MTD-ERV 350.

Monitoring of the external filters* must be connected to the PCB panel (extend- ed version) of the MTD-ERV 350 by the installer.

For cleaning ...

You can clean the filters when necessary:

Remove the mains plug from the plug socket.

Pull the filters (A) out of the MTD-ERV 350.

A

A

Clean the filters (B) using a vacuum cleaner.

B

Push the filters (A) back into the MTD-ERV 350.

Insert the plug of the MTD-ERV 350 into the plug socket again.

Press " For replacement ... " to cancel the filter indication.

For replacement ...

As soon as the filters have to be replaced, proceed as follows:

Remove the mains plug from the plug socket.

Pull the filters (A) out of the MTD-ERV 350.

A

A

Remove the clamps (C) holding the two filter cloths to the filter brackets.

Push the filter cloths (D) off the filter brackets

(F).

C

D

Ensure that the cloth is not damaged by the corners of the filter bracket.

Before putting the MTD-ERV 350 into op- eration the first time, you should clean the filters (and the valves) because the ventilation system may have been soiled with building dust during the building phase.