MTD ERV 365 Malfunction indications on the CC Ease Display à Remedy, Avoid contact with the PCB

Models: ERV 350 ERV 365

1 56
Download 56 pages 39.4 Kb
Page 42
Image 42
4.7.2 Malfunction indications on the CC Ease Display à Remedy

4

4.7.2 Malfunction indications on the CC Ease Display à Remedy

Thissectioncontainstipsonremedyingthemalfunctionsdescribedinsection4.7.1thatcanappearontheCCEase display.

’FiL‘ ’tEr’ in display

Remove plug from socket

Clean or replace filter

Mount filter with the rounded part of the handle pointing downwards

Reinsert the

plug in the socket

Press

until ’FiL‘ ’tEr‘ disappears

CAUTION!

Avoid contact with the PCB

and frost protection element due to risk of electrocution

Yes

Then initiate the self-test (P76 on 1)

Do the fan

and the PCB

Yesregister current (1.5 – 10 VDC)?

Remove the heat exchanger

and the foam part of the bypass and replace the fan

E1 / E2

Exhaust air/supply air fan malfunction

Remove the filter,

the plastic front cover and the metal cover

Do the fan

connection and the PCBNo register 230 VAC?

Replace the PCB

CAUTION: Reset unit

No

Replace the PCB

CAUTION: Reset unit

Left-hand or right-hand version of the MTD-ERV 350?

See illustration on plastic cover for location of PCB

ERV 350 Left: Supply fan left

ERV 350 Right: Supply fan right

38 Instructions for the Installer

Page 42
Image 42
MTD ERV 365, ERV 350 manual Malfunction indications on the CC Ease Display à Remedy, Instructions for the Installer, E1 / E2