Menu P5 ! Setting additional control functions

4

Menu P5 ! Setting additional control functions

 

 

Values for additional control functions

Sub-menu

Description

Minimum

Maximum

Standard

P50

Activation of

0 (= No)

1 (= Yes)

0

 

the chimney sweep control system.

 

 

 

P51

Indicate whether

0 (= No)

1 (= Yes)

0

 

preheater is installed.

 

 

 

 

 

 

 

 

Note:

change only if a preheater was subsequently installed.

If the MTD-ERV 350 has to be reset to the works settings via P75, a subsequently installed preheater will be reset as standard to "ABSENT".

Check the presence of the preheater after a general reset via menu P75.

P52

Setting the

0

3

2

 

preheater control.

 

 

 

 

ϖ

Level 0

 

 

 

 

ϖ

Particularly safe setting.

 

 

 

 

Level 1

 

 

 

 

ϖ

Safe setting.

 

 

 

 

Level 2

 

 

 

 

ϖ

Nominal setting.

 

 

 

 

Level 3

 

 

 

 

 

Economy setting.

 

 

 

Note:

ThePREHEATERISSWITCHEDONEARLIESTWITHTHEparticularlysafesetting.Thislevelthusoffersthe greatest safety for maintaining balanced ventilation. On the other hand, the preheater is switchedonthelatestintheECONOMYSETTING.Thislevelthusofferstheleastsafetyformaintain- ing balanced ventilation.

During commissioning of the MTD-ERV350 the preheater control can generally be left on Level 2:NOMINAL SETTING (= works setting).Only in areas with cold winters (with daytime tem- peraturesregularlyapprox.-10°Corbelow)shouldLevel1:SAFESETTINGorevenLevel0:PARTICU-

LARLY SAFE SETTINGS be selected.

 

 

 

 

Values for additional control functions

Sub-menu

Description

 

Minimum

Maximum

Standard

P53

Indicate presence of an extractor hood.

 

0 (= No)

1 (= Yes)

0

 

Note:

 

 

 

 

 

If an extractor hood is connected to the

 

 

 

 

 

ventilation system, the user can set the

 

 

 

 

 

ventilation levels for the extractor hood

 

 

 

 

 

via P29.

 

 

 

 

P54

Indicate presence of a bypass.

 

0 (= No)

1 (= Yes)

1

 

Note:

 

 

 

 

 

The MTD-ERV 350 is equipped with a by-

 

 

 

 

passasstandard.Thevaluecantherefore

 

 

 

 

be left at '1'.

 

 

 

P55

Indicate presence of a post-heater.

0 (= No)

1 (= Yes)

0

P56

Setting the necessary air volume for the

nL

HL

nL

 

dwelling.

 

 

 

 

nL: "Normal air volume".

 

 

 

 

HL: "High air volume".

 

 

 

Note:

Setting the air volume in P56 (to "nL" or "HL") forms the basis for setting the air specifications and hence for setting the fans. For further information, see section 4.5 and P30 to P37.

Instructions for the Installer 31