Menu P8  Open-loop and closed-loop control

4

 

 

Values (malfunction) information

Sub-menu

Description

Minimum

Maximum

Standard

P75

Complete reset.

0

0

0

 

Press

 

 

 

 

" " for 5 seconds to carry out a com-

 

 

 

 

plete reset.

 

 

 

 

A complete reset returns all settings to

 

 

 

 

the original works settings.

 

 

 

After a complete reset, the MTD-ERV 350 prompts you to enter “nL / HL” (see P56) and “Li / Re” (see P57) again.

After a complete reset, all settings in menus P2 and P3 and the existing controls P5 and P6 have to be made again.

If the MTD-ERV 350 is equipped with a preheater, this must be logged in again in menu P51, as it is set to "Logged out" as standard after a complete reset.

P76

Self-test of the MTD-ERV 350.

0

1

0

 

 

 

Explanation

The MTD-ERV 350 switches to the highest level immediately after activation of the self-test.In addi- tion,thebypassvalveopensandclosesimmediatelyafteractivationoftheself-test.Ifthisself-testis completed without malfunctions, the valve of the preheater (if installed) then opens and closes.

Menu P8 Open-loop and closed-loop control

Selection between open-loop and closed-loop control

Sub-menu Description

P80 0= Open-loop control 1 = Closed-loop control (by analogy with input 1)

P81

0= Open-loop control 1 = Closed-loop control (by analogy with input 2)

 

 

P82

Min. setting by analogy with input 1

 

 

P83

Max. setting by analogy with input 1

 

 

P84

Min. setting by analogy with input 2

 

 

P85

Max. setting by analogy with input 2

Max

Min

0 V

10

Instructions for the Installer 33

Page 37
Image 37