Multi-Link ML-100, ML-001 manual Door/Window Sensor WD-101, Repeater RP-434, Water Sensor FS-101

Models: ML-001 ML-100

1 30
Download 30 pages 7.01 Kb
Page 10
Image 10

INSTALLATION

4.Insert the rechargeable battery to the battery compartment. There are 2 different types of rechargeable battery for 2 markets:

ACCESSORIES

Additional sensors and transmitters as well as add on accessories are available to work with your system.

a.North American Version: Lead Acid Connect the 2 wires to the battery. Red wire

connects to the “+” terminal on the battery. Black wire connects to the “-” terminal on the battery. Markings on the battery should face up.

b. European Version: Ni-MH

Plug in the wire from the battery to the battery socket inside the battery compartment.

5. After inserting the rechargeable battery, the LO BATT LED will be off if the battery is fully charged, otherwise it will be on.

6.Connect the phone line from the wall socket to the “LINE” socket inside the battery compartment.

7.[OPTIONAL] If another telephone that will be using the same telephone jack, you may connect this telephone to “PHONE” outlet of the control panel by a phone cord (not provided).

8.The phone line(s), cord of the power adapter should all come out from the lower right corner of the control panel in order to close the battery cover properly.

9.The battery cover can now be closed, and tighten the 2 screws to secure the battery cover.

PWR, ARM, PROG LEDs should be flashing, zone LEDs should be off.

10.The control panel is intended to be mounted on a flat wall. 2 screws are required to mount the control panel securely on the wall. It should not be mounted too high or too low. In most situations, just below eye level is ideal.

(Optional)

7-1/8"

Door/Window Sensor (WD-101)

-Magnetic Contact Sensor

-For all doors or windows

- Batteries included

Repeater (RP-434)

- Extend the operation range between 2 wireless devices, such as any sensors and control panel

- Doubles the operation range automatically between sensors and control panel

Water Sensor (FS-101)

- Alerts you when water is detected

- Ideal for water detection in basement, under the sink, even bathroom

Garage Door MonitorTM Sensor (GS-101)

(Available in US and Canada) - Monitors your garage door

- Alerts you when the garage door is left open

Garage Door MonitorTM Sensor (GS-102)

(Available outside US and Canada) - Monitors your garage door

- Alerts you when the garage door is left open

11.Once you have selected the mounting location, tighten 2 screws on the wall. They should be

7-1/8" apart from each other, on the same horizontal level. Do not tighten the screws all the way in, leave about 1/8" from the wall in order for the control panel to be hanged onto the wall.

8

Indoor/Outdoor Motion Sensor (PS-101)

-Monitors area in a 110 degree ARC and up to 40 feet away from the sensor