INSTALLATION
Phone Number Programming
You can program up to 6 Emergency Phone Numbers. When the system is in panic, the control panel will call these phone numbers and announce its status.
The 6 emergency phone numbers include:
-5 voice message phone numbers
-1 Contact ID message phone number
Program the following for Voice Message Phone Numbers
-Phone memory (from 1 to 5), this is where the phone numbers will be stored
-Phone number, up to 29 digits.
-Redial count, this is how many times that phone number will be called, from 1 to 9 times.
-Repeat count, this is how many times the emergency message will be repeated, from 1 to 9 times.
Step | Keys | Function | Description | Note | |
|
|
|
|
| |
1 | [PROG] | Enter | Enter master password to | 3 beeps for valid | |
Programming | programming mode | password. 1 long beep | |||
| [MPIN] | ||||
| mode |
| for invalid password. | ||
|
|
| |||
2 | [1] | Select phone |
| You will hear [Enter | |
|
| number |
| phone memory]. | |
|
| programming |
|
| |
|
|
|
|
| |
3 | [1] to [5] | Enter phone | During emergency, phone |
| |
memory 1 will be called first, |
| ||||
|
| memory |
| ||
|
| then phone memory 2, 3, 4, and |
| ||
|
|
|
| ||
|
|
| 5. So phone memory 1 has |
| |
|
|
| higher priority. |
| |
|
|
|
|
| |
4 | [Phone | Enter phone | Phone number can be up to 29 | You will hear [Enter | |
number] | number | digits.** | Redial]. | ||
| |||||
| + [Arm] |
|
|
| |
|
|
|
|
| |
5 | [1] to [9] | Enter Redial | Redial is the number of times | You will hear [Enter | |
| + [Arm] | count | that phone number will be | Repeat]. | |
| called. Each phone number |
| |||
|
|
|
| ||
|
|
| can have a different redial |
| |
|
|
| count, from 1 to 9 times. |
| |
|
|
|
|
| |
6 | [1] to [9] | Enter Repeat | Repeat is the number of times | You will hear [Phone | |
| + [Arm] | count | that voice emergency message | Accepted] indicating the | |
| will be played, from 1 to 9 times. | phone number and its | |||
|
|
| |||
|
|
| It is recommended to set up | settings have been | |
|
|
| the repeat time to 5 or more. | programmed successfully. | |
|
|
|
|
|
**Note:
You may enter a
TROUBLE SHOOTING
Control Panel
Questions | Solutions |
|
|
Why I can’t arm my system? | Make sure none of the sensors are |
| triggered. You can check this by the zone |
| LEDs, none of them should blink. |
|
|
I cannot arm the system even when no | You need to disarm the system again by |
sensor is triggered, and the ARM LED | either entering the password or disarm by |
is off. | keychain remote. Although the ARM LED |
| is off, but the system is not completely |
| disarmed after an alarm was triggered. |
| Refer to page 22 on how to completely |
| disarm a control panel after an alarm has |
| been triggered. |
|
|
Why the ARM LED keeps flashing? | That means you have not programmed any |
| emergency phone numbers. For instructions |
| on how to program emergency phone |
| numbers, please see page 10. |
|
|
How do I exit programming mode | You can press the programming button on |
when I’m in the middle of it? | the side of the unit to quit programming |
| anytime. |
|
|
When a sensor is triggered, the alarm | You have programmed that sensor in alarm |
sounds instantly even it is not armed, | mode, instead of beep mode. Please refer |
why is that? | to page 29 for instructions of how to program |
| it back to beep mode. |
|
|
When the alarm is triggered, why | The control panel will stop calling when it |
the control panel won’t call all the | is disarmed by any one of the recipients. |
programmed phone numbers? It | Disarm can also be done locally thru the |
always stops before calling the | keypad on the control panel by entering a |
last number. | valid password. |
|
|
Why the control panel doesn’t beep | You have placed the buzzer mode selector |
when a sensor is triggered, while | on the side of the control panel to “II”, this |
only the zone LED flashes? | will disable the beeping. Placing it to “I” will |
| enable the beeping. |
|
|
The control panel is in armed mode, | If the triggered sensor is programmed in the |
why activating a sensor will not cause | Alert Zone (Bypass Zone), alarm will not |
an alarm, or call any emergency phone | sound, and emergency call will not be made |
number? | if this sensor is triggered. The control panel |
| will only respond when it is disarmed, in |
| alert mode. |
|
|