INSTALLATION

Contact ID Phone number

You can program a telephone number for calling to the central monitoring station. When the system is in panic, the control panel will call this phone number and will send out a Contact ID message with event code 140, which represents “General Alarm”.

HOME AUTOMATION

Event Trigger

You can control up to 5 different devices not only manually, but also automatically. It is called Event Trigger. That means when a sensor is triggered, the control panel will transmit a signal to activate the designated control module. Applications include:

Follow the instructions below to program the necessary info in order to call a monitoring station:

-Phone number of central monitoring station (up to 29 digits)

-Account number given by the Central Monitoring Station

Phone Number Programming (Calling to Central Monitoring Station)

Step

Keys

Function

Description

Note

1

Press [PROG]

Enter Program-

Enter master

3 beeps for valid

 

Press [MPIN]

ming mode

password to

password. 1 long

 

 

 

programming mode

beep for invalid

 

 

 

password.

 

 

 

 

 

 

 

 

 

2

Press [1]

Select phone

 

You will hear

 

number

 

[Enter Phone

 

 

 

 

 

programming

 

Memory]

-Lights on when you open the front door (walking into a room, lights on automatically), this is called "Event Trigger on".

-Lights off when you open a door. (walk away from a room, turns lights off), this is called "Event Triggered off".

Event trigger is only applicable to the sensor(s) and control module in the same zone. For example, you can program control module 1 to be on or off when zone 1 sensor(s) is triggered. You can also program control module 2 to be on / off when zone 2 sensor(s) is triggered.

Factory Default: This feature is disabled for all zones at the factory.

Event Trigger On

Event Trigger Off

3

Press [0]

Enter phone

During emergency,

You will hear

 

 

memory

the Contact ID phone

[Phone Zero]

 

 

 

number has the highest

 

 

 

 

priority, it will be the

 

 

 

 

first number to call.

 

 

 

 

 

 

4

Enter [Phone

Enter phone

Phone number

You will hear

 

number] +

number

can be up to 29

[Phone Accepted]

 

[Arm]

 

digits.

indicating the phone

 

 

 

 

number has been

 

 

 

 

programmed

 

 

 

 

successfully.

12

To change the event trigger setting follow the instructions below.

Step

Keys

Function

Description

Note

 

 

 

 

 

1

[PROG]

Enter Program-

Enter master

3 beeps for valid

ming mode

password to

password. 1 long beep

 

[MPIN]

 

 

 

programming

for invalid password.

 

 

 

mode

 

 

 

 

 

 

2

[7]

Select Event

 

After [7] is entered,

 

 

Trigger

 

some zone LEDs will be

 

 

 

 

off, on or flash. This

 

 

 

 

indicates the setting of

 

 

 

 

event trigger.

 

 

 

 

 

3

Disable Event

Select which

Refer to the

If event trigger “ON” is

 

Trigger: [1] to

zone you would

diagram below

enabled, that zone LED will

 

[5]

like to enable /

to select the

be on. If event trigger “OFF”

 

 

disable event

appropriate

is enabled, that zone LED

 

Enable Event

trigger.

setting.

will flash. If it is disabled, the

 

 

 

zone LED will be off. You are

 

Trigger: [6] to

 

 

 

 

 

allowed to make multiple

 

[0].

 

 

 

 

 

changes before terminating

 

 

 

 

 

 

 

 

programming mode.

 

 

 

 

 

4

[PROG]

Terminate

 

PROG LED

 

when

programming

 

will be off.

 

finished.

mode.

 

 