COMMUNICATION

Receiving the Emergency Call

If you are on the list as one of the recipients of the emergency call, you should read the following instructions carefully. You should also notify all the persons you will be calling so they know how to react when they receive the emergency call.

The control panel will call you when there are emergencies such as break-ins, smoke, fire events, or someone at home needs assistance.

1.When the phone rings at the calling location, the person who answers the phone will hear a message related to the emergency events, such as “System Panic”, or “Zone 1 Sensor 1 Triggered” etc. This message may be repeated several times depending on how it was programmed.

ADVANCED PROGRAMMING

Follow the procedures below to program the beep / alarm setting.

Step

Keys

Function

Description

Note

1

[PROG]

Enter Programming Enter master

3 beeps for valid password.

 

[MPIN]

mode

password to

1 long beep for invalid

 

 

 

programming mode password.

 

 

 

 

 

2

[5]

Select Beep /

 

After [5] is entered, some zone

Alarm Setting

 

LEDs will flash or stay on.

 

 

 

 

 

 

 

This indicates whether that

 

 

 

 

zone is set to beep or alarm.

 

 

 

 

 

3

Set to Beep:

Select which

Refer to the

If Alarm is set for that zone,

 

[1] to [5]

zone you would

diagram below to

that zone LED will be on. If

 

 

like to Beep or

select the appro-

Beep is set, the LED will

 

Set to Alarm:

Alarm.

priate setting.

flash. You are allowed to

 

[6] to [0].

 

 

make multiple changes before

 

 

 

terminating programming

 

 

 

 

 

 

 

 

mode.

2.After the message has been repeated for a certain number of times, the control panel will ask for a valid password, you will hear “Enter Password”.

3.Enter the 4-digit password to have access to the control panel. If a valid password is accepted, you will hear “Password Accepted”, otherwise, you will hear “Password Failure”.

4.After entering the correct password, you can follow the “Phone Command” instruc- tions to perform the required tasks, such as disarm, turn on / off devices or check the system status etc. For further information of how to control the system remotely, please refer to the next section, "Remote Operation by Telephone".

Zone 1

Sensor 1

Triggered

Enter

Password

-Arm

-Disarm

-Check status

-Control lighting etc. -Disconnect

4

[PROG] when

Terminate pro-

PROG LED will be off, and

 

finished.

gramming mode.

you will hear 3 beeps.

 

 

 

®

 

 

BEEP

ALARM

 

 

Zone 1

Button [1]

Button [6]

This row

:

Zone 2

Button [2]

Button [7]

Buttons for Beep

Zone LED : Flash

 

 

 

Zone 3

Button [3]

Button [8]

 

 

Zone 4

Button [4]

Button [9]

 

 

Zone 5

Button [5]

Button [0]

This row

:

 

 

 

Buttons for Alarm

 

 

 

Zone LED : ON

Example:

If you would like to change the setting for zone 5 from “Beep” to “Alarm”, simply press [0] at step 3.

This will change the zone 5 setting to “Alarm”.