Terminal Adapter AT Commands & S-Registers

S30

Online Inactivity

S32

Escape sequence timeout

S34

Maximum escape sequence length

S50

Caller line ID (CLI)

S52

Auto-protocol detection

S54

Forces 56KBps B-Channel Data Rate

S55

POTS Port Call Control

S56

Calling Party Number IE Settings

S57

Called Party Number IE Settings

S75

Maximum V110 Network Rate

S76

V110 Network Rate

S77

V110 Network Rate Control

S80

Persistent DTR Dialing Delay

S0 Number of Rings Until Answer

Unit: 1 ring

Range: 0–255

Default: 1

Sets the number of rings the TA waits for before it answers and begins its connect sequence. S0=0 turns off the ability to automatically answer a call. S0=1 causes the TA to automatically answer after 1 ring. Note that if the S0 value is set too high, the calling device may time out before the TA answers the call. For autoanswer, S0 must have a nonzero value, DTR must be high (&D command), and the TA must be offline.

S1 Ring Count Unit: 1 ring Range: 0–255 Default: 0

Counts the number of rings that have occurred, up to a maximum of 255. It is a read-only register and is seldom, if ever, used in typical operation.

S2 Escape Character Unit: Decimal ASCII code Range: 0–127

Default: 43 (+)

MultiModemISI Hybrid Series, ISIHP-2S/2U/4S/4U/4SD

127

Page 127
Image 127
Multi-Tech Systems ISIHP-4S, ISIHP-4U S0 Number of Rings Until Answer, S2 Escape Character Unit Decimal Ascii code Range