MultiModemISI Hybrid Series, ISIHP-2S/2U/4S/4U/4SD 115
Terminal Adapter AT Commands & S-Registers
Serial Port Configuration Commands
Use the following commands to control the interaction between the TA and
the computer connected to it.
En Command Mode Echo
Values: n = 0 or 1
Default: E1 (Echo on)
When you enter commands, the TA echoes the characters back to the
computer or terminal where they appear on the monitor. This command
turns this feature on and off.
E0 Echo off
E1 Echo on
L5 and L6 List Active Profile
Values: n = 5 or 6
Default: none
Lists current operating parameters of the TA. This information is useful
when changing communications software or when changing default settings.
ATL5 lists AT command parameters, and ATL6 lists values currently stored
in the S-Registers.
L8 Lists Low Level ISDN Status
Qn Enable/Disable Result Codes
Values: n = 0, 1, or 2
Default: Q0 (Enable result codes)
Controls whether the TA sends result codes to the computer. (Use the V
command to select the format of the result codes.)
Q0 Enable result codes.
Q1 Disable result codes (quiet mode) for
applications such as computer-controlled
auto dialing.
Sr=n Set S-Register
Values: r = 0, 25, 7, 8, 10, 25, 32, 34, 50, 52-57, 75-
77, 80; n varies
Default: None