Terminal Adapter AT Commands & S-Registers

Specifies the character used by the TA to escape from data mode and return to command mode.

S3 Carriage Return Character Unit: Decimal ASCII code Range: 0–127

Default: 13 (^M)

Specifies the character used by the TA to indicate the end of a command line.

S4 Line Feed Character Unit: Decimal ASCII code Range: 0–127

Default: 10 (^J)

Specifies the character used by the TA to indicate the end of a status message.

S5 Backspace Character Unit: Decimal ASCII code Range: 0–32, 127 Default: 8 (^H)

Specifies the character used by the TA to delete the previous character in command line.

S7 Wait for Connection (Abort Timer)

Unit: 1 second

Range: 0–255

Default: 45

Sets Abort Timer delay time, which is the length of time TA waits for a connection after dialing. If no connection is established during the specified time, the TA ends the call.

S8 Pause Time for Comma Unit: 1 second Range: n=0-255 Default: 2 (= 2 seconds)

S8 sets the length of the pause caused by a comma inserted in a dialing command. The default setting is 2 seconds, where each unit is one second. S8 may be set for up to 255 seconds.

128

MultiModemISI Hybrid Series, ISIHP-2S/2U/4S/4U/4SD

Page 128
Image 128
Multi-Tech Systems ISIHP-4SD, ISIHP-4U manual S3 Carriage Return Character Unit Decimal Ascii code Range