Owner’s Manual

9.If you are required to dial 9 to get an outside line, edit the dialing prefix to include a 9 and a comma, e.g., ATDT9, (the comma inserts a pause before dialing the next digit).

Similarly, to turn off call waiting for the duration of the call, insert the disabling code used in your area, e.g., ATDT*70,. If you are using Windows 95-compliant software, make these changes in the How I dial from this location box of Dialing Properties.

Note: *70 is used only in the United States.

Remote Configuration

Remote configuration is a network management tool that allows you to configure modems anywhere in your network from one location. With password-protected remote configuration, you can issue AT commands to a remote MT5634ZPX-PCI modem for maintenance or troubleshooting as if you were on-site.

Basic Procedure

Use these steps for connections established by the local or by the remoteMulti-Tech modem.

1.Establish a data connection with a remote MT5634ZPX-PCI modem.

2.Send three remote configuration escape characters followed by AT and the setup password. Then press ENTER. Example:

%%%ATMTSMODEM<cr>. You have four attempts to enter the password correctly before being disconnected. If the password is correct, the remote modem responds with OK.

3.You now can send AT commands to configure the remote modem.

4.When you finish configuring the remote modem, save the new configuration by typing AT&W0<cr>. Then type ATO<cr> to exit remote configuration. You can then break the connection in the normal way.

CAUTION: Hanging up while you are in remote configuration mode can lock up the remote modem.