Owner’s Manual

Register

Unit

Range

Default Description

 

S48

decimal

7 or 128

7

The chart below lists the S36 and S48

 

 

 

 

configuration settings necessary to

 

 

 

 

negotiate certain types of connections.

 

 

 

 

S48=7

S28=128

 

 

S36=0,2

LAPM or Hangup

Do not use

 

 

S36=1,3

LAPM or Async

Async

 

 

S35=4,6

LAPM, MNP, or Hangup MNP or Hangup

 

 

S36=5,7

LAPM, MNP, or Async

MNP or Async

S89

seconds

0, 5–255

60

Sets the length of time in the off-line

 

 

 

 

command mode before the modem

 

 

 

 

goes into standby mode. A value of

 

 

 

 

zero prevents standby mode; a value

 

 

 

 

of 1–4 sets the value to 5.

S108

decimal

0-3, 6,7

6

Selects the digital loss if using the

 

 

 

 

modem thru a PBX line. Default

 

 

 

 

value is -6dB loss, the value used

 

 

 

 

when calling from a typical POTS

 

 

 

 

line long distance.

 

S109

 

0, 1, 2

 

Sets one of three 56K operating

 

 

 

 

modes: K56flex mode, V.90 mode, or

Auto-mode.

0 V.90 disabled

1 K56flex or V.90 (Dual-mode enabled)

2 V.90 only (K56flex disabled). Forces V.90 connections for testing purposes, etc.