Technical Configuration

 

 

MultiVOIP FX User Guide

 

 

 

 

 

 

 

 

 

 

 

FXS Loop Start Interface: Parameter Definitions (cont’d)

 

 

Field Name

Values

Description

 

 

FXS Options fields

 

 

 

 

 

 

 

 

Ring Count ,

1-99

Maximum number of rings that

 

FXS

 

the MultiVOIP will issue before

 

 

 

 

giving up the attempted call.

 

 

Current Loss

Y/N

When enabled, the MultiVOIP

 

 

 

 

will interrupt loop current in

 

 

 

 

the FXS circuit to initiate a

 

 

 

 

disconnection. This tells the

 

 

 

 

device connected to the FXS

 

 

 

 

port to hang up. The Multi-

 

 

 

 

VOIP cannot drop the call; the

 

 

 

 

FXS device must go on hook.

 

 

 

 

 

 

 

Flash Detection Range fields

 

 

 

 

 

 

 

 

Min/Max

for Min. and Max.,

For a received flash hook to be

 

 

 

50 - 1500

regarded as such by the

 

 

 

milliseconds

MultiVOIP, its duration must

 

 

 

 

fall between the minimum and

 

 

 

 

maximum values given here.

 

 

 

 

 

 

 

 

 

 

 

 

Caller ID fields

 

 

 

 

 

 

 

 

Type

Bellcore

The MultiVOIP currently

 

 

 

supports only one

 

 

 

 

implementation of Caller ID.

 

 

 

 

That implementation is Bellcore

 

 

 

 

type 1 with Caller ID placed

 

 

 

 

between the first and second

 

 

 

 

rings of the call.

 

 

Enable

Y/N

Caller ID information is a

 

 

 

 

description of the remote

 

 

 

 

calling party received by the

 

 

 

 

called party. The description

 

 

 

 

has three parts: name of caller,

 

 

 

 

phone number of caller, and

 

 

 

 

time of call. The ‘time-of-call’

 

 

 

 

portion is always generated by

 

 

 

 

the receiving MultiVOIP unit

 

 

 

 

(on FXS channel) based on its

 

 

 

 

date and time setup.

 

 

 

 

 

 

80

Page 80
Image 80
Multi-Tech Systems MVPFX2-2 manual For Min. and Max