ENGINE OPERATING PANEL

ENGINE OPERATING PANEL

The definitions below describe the controls and functions of

the DCA-180SSJU

(Figure 8).

 

 

 

9

 

1

 

 

3

 

 

10

 

2

 

 

4

 

 

11

 

AUTO

MANUAL

 

 

OFF/RESET

 

5

LOW OIL PRESSURE

13

HIGH COOLANT TEMPERATURE

OVERCRANK

 

OVERSPEED

 

 

ENGINE RUNNING

 

 

MOOOOO-20001Q

 

 

6

 

 

 

 

8

 

 

7

12

 

14

 

 

Figure 8. Engine Operating Panel

1.Panel Light – Normally used in dark areas or at night time.When activated, panel lights will illuminate.When the generator is not in use be sure to turn the panel light switch to the OFF position.

2.Panel Light Switch – When activated will turn on control panel light.

3.Oil Pressure Gauge – During normal operation this gauge be should read between 35 to 65 psi. (241~448 kPa).When starting the generator the oil pressure may read a little higher, but after the engine warms up the oil pressure should return to the correct pressure range.

4.Water Temperature Gauge – During normal operation this gauge be should read between 180° and 230°F. (82° C and 110° C

5.Charging Ammeter Gauge – Indicates the current being supplied by the engine’s alternator which provides current for generator’s control circuits and battery charging system.

6.Fuel Gauge - Indicates amount of diesel fuel available.

7.Tachometer – Indicates engine speed in RPM’s for 60 Hz operation. This meter should indicate 1800 RPM’s when the rated load is applied. In addition a built in hour meter will record the number of operational hours that the generator has been in use.

8.Engine Speed Switch – This switch controls the speed of the engine (low/high).