Multiquip DCA180SSJU operation manual Setup, Circuit Breakers, Lubrication Oil, Fuel Check

Models: DCA180SSJU

1 106
Download 106 pages 14.07 Kb
Page 48
Image 48
SETUP

SETUP

Circuit Breakers

To protect the generator from an overload, a 3-pole, 500

amp,

circuit breaker is provided to protect the

 

 

from overload. In addition two

single-pole, 20 amp

circuit breakers are provided to

protect the GFCI receptacles from overload. Three 50 amp circuit breakers have also been provided to protect the auxiliary receptacles from overload. Make sure to switch ALL circuit breakers to the OFF position prior to starting the

engine.

Lubrication Oil

Fill the engine crankcase with lubricating oil through the filler hole, but DO NOT overfill. Make sure the generator is level. and verify that the oil level is maintained between the two notches (Figure 31) on the dipstick. See Table 9 for proper selection of engine oil.

Figure 31. Engine Oil Dipstick

When checking the engine oil, be sure to check if the oil is clean. If the oil is not clean, drain the oil by removing the oil drain plug, and refill with the specified amount of oil as outlined in the John Deere Engine Owner's Manual. Oil should be warm before draining.

Other types of motor oils may be substituted if they meet the following requirements:

API Service Classification CC/SC

API Service Classification CC/SD

API Service Classification CC/SE

API Service Classification CC/SF

 

Table 9. Recommended Motor Oil

 

 

F

C

 

 

 

OIL: SAE

 

 

 

 

 

 

 

 

 

 

 

 

 

122

50

 

 

 

 

 

 

 

 

 

104

40

10W40

30

OIL

5W30

10W/40

15W30

10W30

10W

20W40

86

30

 

 

 

 

 

 

 

 

 

68

20

 

 

 

 

 

 

 

 

 

50

10

 

 

 

 

 

 

 

 

 

32

0

 

 

 

 

 

 

 

 

 

-14

-10

 

 

 

 

 

 

 

 

 

-4

-20

 

 

ARCTIC

 

 

 

 

 

 

-40

-40

 

 

 

 

 

 

 

 

-22

-30

 

 

 

 

 

 

 

 

 

Fuel Check

DANGER - EXPLOSION/FIRE HAZARDS

Fuel spillage on a engine can cause a or

. If fuel spillage occurs, wipe up the spilled fuel

completely to prevent fire hazards. NEVER smoke around or near the generator.

Refilling the Fuel System

CAUTION - REFUELING THE GENERATOR

ONLY properly trained personel who have read and understand this section should refill the fuel tank system.

This generator has an internal fuel tank located inside the trailer frame and may also be equipped with an environmental

fuel tank (Figure 32).

fill the fuel tanks with clean

fresh

DO NOT fill the fuel tanks beyond their

capacities.

 

 

Pay attention to the fuel tank capacity when replenishing fuel.The fuel tank cap must be closed tightly after filling. Handle fuel in a safety container. If the container does not have a spout, use a funnel. Wipe up any spilled fuel immediately.

Figure 32. Internal Fuel Tank System

PAGE 48 — DCA-180SSJU — OPERATION AND PARTS MANUAL — REV. #3 (02/01/10)