Glossary
Page 30 | WI1424A 1/06 |
the
Cancel Next Test Timer Report on Any Report See Test Timer
Central Station Receiver Data Format See Data Format
Chime (Displays "MONITOR" on
This annunciator feature may be used on any zone to sound a tone at the keypad while disarmed when the zone goes into trouble. Access the ACTIVATE CHIME function to enable or disable the Chime Mode. This feature is programmable by zone and "Chime Timeout Duration". A time must be programmed for the chime to function. Note: "0" means no chime value is programmed.
Chime Zone 2
CHIME2 adds an additional tone onto the regular "Chime Zone" tone. It allows some zones to have distinctive annunciator chimes to identify the door or zone. "Chime Zone" must be selected on any keypad for all area keypads to chime. While the standard chime zone sounds a steady tone when a chime zone is faulted, Chime 2 will sound a pulsating tone when a Chime 2 zone is faulted. This can be used to help the customer easily identify the door which has been opened. Program the zone as Chime 2 in the Zone Features screen. This feature is programmable by zone and "Chime Timeout Duration".
Chirp Output on Keyfob Arm/Disarm
If enabled, when arming with a keyfob, the PGM2 output chirps.
Clear Program
Caution: Erases the dealer program. Use this feature to start a new customized default program. Access Address Location, then press the Uor Dbutton.
Closing Report; Closing Report Only on Conditional Closing; Conditional Closing; Include Selective/Group Bypass In Conditional Closing/Status; Status Report; Disable Closing Report
On arming, the communicator can transmit a unique Closing Code for each user and a status report that identifies the problem zone to the central station. Note that Subscriber Identification Numbers and a Closing Code and/or conditional closing code must be entered for any closing report.
Select which users will report closings for each telephone number, even if "Closing Report Only on Conditional Closing" is selected. Normally, a closing report will consist of the Closing Code and the number of the user that armed. If the user armed with an auto- bypassed zone (or selective/group bypassed zone if "Include Selective/Group Bypass In Conditional Closing/Status" was programmed), the Conditional Closing Code will also be sent.
Select "Closing Report Only on Conditional Closing" to report only when arming with an
Select "Status Report" to send a closing followed by a status report that identifies the problem zone(s). A typical Status Report is represented by the following example.
Example (4/2 Format). A burglar breaks into a commercial establishment during the night, breaking the window foil on Zone 5. The Open/Close Subscriber Identification Number is "1234"; the Alarm Code for Zone 5 is "3,5" (Burglary Zone 5); the Subscriber Identification Number is "6789"; the Closing Code is "C". The communicator will send the following report to the central station.
When alarm occurs:
"6789 35" – Alarm, Zone 5 Closing Report:
"1234 C1" – Closing, User 1 (User 1 returned, inspected damage & rearmed; the same transmission would occur for User 11, 21, 31, etc.)
"1234 F5" – Trouble, Zone 5 (zone status at time of closing: Window foil still broken; Zone 5
Cold Start
Caution: Erases the entire program (codes, schedules, etc.), and loads the following defaults: 8 hardwire zones (Zones
Default Code of "456789". Press Cto exit the EZ Program menu. Access Location Cold Start, then press the Uor Dbutton.
Data Format
X | LNAPCO Security Systems |