Glossary
Page 40 | WI1424A 1/06 |
external remote mounting, and one module may be used with the
Relay Follows Zone
External Relays can be programmed to follow a zone. If values are entered in Time locations, the relay will time out after the programmed time.
Remote Panic See Panic Zone
Report Digital Dialer Exit Error/Recent Closing
A Recent Closing transmission is sent if an alarm occurs within two (2) minutes after the expiration of the Exit Time. If the user num- ber is available, it is included in the Recent Closing transmission. Note: Recent Closing transmissions are not sent for fire alarms.
Report Telco 1; Report Telco 3 (Double or Split Reporting)
Alarms, alarm restores, troubles and trouble restores may be selected individually for each zone. Violation of a zone selected to report will communicate the code(s) selected for that zone to the central station.
Normally, Report Telco 1 is used to report to the central station. Report Telco 3 is used when certain zones will report to a different receiver (split reporting); Report Telco 1 and Report Telco 3 are both used on the same zone to report to two receivers successively (Double Reporting). (Double Reporting requires a successful report to Telco 1 before reporting to Telco 3). Also see Backup Report on Telco 2.
Reset Day Zone with Arm/Disarm Only See Day Zone
Residential Fire
Prevents battery depletion during alarm. Must be programmed in Residential Fire Installations.
Security Bypass
Recommended for commercial applications, requires entry of a valid user code. A typical application would be a warehouse or ship- ping terminal where the overhead doors are programmed for 24 hour protection and must be Bypassed to allow access, and then Un- bypassed again. To activate this feature, DO NOT program Disable Code Required for EZ Bypass is Program BE (Bypass Enable) for each user who is to have this ability.
To Security Bypass a zone:
1.Enter a code valid for bypass (Authority Level 1 or higher and Bypass option enabled), then press the Bbutton; BYPASS ENABLED will display.
2.Press the Bbutton, then the zone number (or vice versa) to deactivate that zone. Similarly, a bypassed zone may be un-
bypassed using the same procedure. Note: When the panel is subsequently disarmed, all bypassed zones revert to unby- passed zones (unless Disable
•It is not possible to Bypass/Unbypass Zones using the Directory Mode procedure.
•Typically, any zone, other then a fire zone, will automatically be unbypassed when the panel is disarmed.
•In order to unbypass a fire zone, follow procedures 1 through 4.
•When a fire zone is bypassed, the panel will go into a fire trouble condition. It will also transmit the fire trouble to the CS, if pro- grammed to do so.
•Zones
Select Alarm Output for Keyfob Chirp
This feature is associated with Chirp Output on Keyfob Arm/Disarm. Normally the chirp on a keyfob arm/disarm is transmitted to the PGM2 output. Selecting "Select Alarm Output for Keyfob Chirp" causes the "Bell" to chirp instead of the PGM2 upon remote arm- ing.
Selective Bypass
Disable Code Required for EZ Bypass (Not for UL installations)
Any or all zones
X | LNAPCO Security Systems |