WI1424A 1/06 | Page 43 |
positive or negative temperature. If the temperature of 0 degrees is required, "negative zero"
is depressed and held down for 2 seconds, the date will display for 5 seconds.
Test Timer; Cancel Next Test Timer Report on Any Report
The test timer schedule is programmed via the Easy Program Menu and using Napco's Quickloader Software. If "Test Timer" is programmed, an automatic test report will be transmitted to the central station on the scheduled day(s) at the scheduled time. To report test timer, select Report Test Time to Telco 1 or 3 and program a report code. Program the Test Timer reporting time and day of the week. If "Cancel Next Test Timer Report on Any Report" is programmed, any report will cause the next
Timeout
Specifies the length of time that an alarm, alert, or delay will remain active. See Time Selection.
Time Selection
The following times are programmable:
TIME(1) | UNITS | MAX. PROG. TIME |
PGM2 OUTPUT TIMEOUT | MIN. | UNTIMED(2) |
PGM2 OUTPUT ACCESS CONTROL TIME | SEC. | 4 MIN., 15 SEC. (255 SEC.) |
ALARM OUTPUT | MIN. | UNTIMED(1)(2) |
MIN. | UNTIMED(1)(2) | |
PGM1 OUTPUT | MIN. | UNTIMED(2) |
ABORT DELAY | SEC. | 4 MIN., 15 SEC. (255 SEC.)(3) |
CHIME TIME | SEC. | 63.25 SEC. (255 |
10 MIN. | 42 HR., 30 MIN. (2550 MIN.) | |
EXIT DELAY | SEC. | 4 MIN., 15 SEC. (255 SEC.)(4) |
ENTRY DELAY 1 | SEC. | 4 MIN., 15 SEC. (255 SEC.)(4) |
ENTRY DELAY 2 | SEC. | 4 MIN., 15 SEC. (255 SEC.)(4) |
SENSOR WATCH | HRS | 254 HRS. |
CANCEL WINDOW | MIN. | 254 MIN. |
ZONE INTEGRATION TIME | 10 MILLISECONDS | 2.55 SEC. |
ZONE ANDING TIME | SEC. | 255 SEC. |
Time and Date (Keypad) in Dealer Program Mode
The Keypad Time and Date on the
Time and Date (Keypad) in User Program Mode
When using an
Time and Date Message Option
Glossary
In the event of a complete power failure (AC and DC) and the loss of the system clock, when the system is
Select "TouchTone Dialing Only" if the subscriber has TouchTone service. TouchTone dialing is faster than rotary dialing, but not always as reliable.
For the communicator to use TouchTone on all dial attempts, program TouchTone Dialing Only. To use TouchTone on the first attempt with subsequent Rotary dial, program TouchTone Dialing with Rotary Backup. TouchTone Dialing Only will override TouchTone Dialing with Rotary Backup if both are selected. Note that if Backup Reporting is also selected, the communicator will alternate between TouchTone and rotary dial to reach Telephone 1, then Telephone 2. See Backup Report on Telco 2.
Trouble; Fire Trouble
An abnormal zone condition (a break in a
Trouble on a Burglary Zone is automatically displayed at the keypad unless Disable Zone Fault Scrolling is programmed. If a Burglary Zone is in trouble, it will go into alarm about 10 seconds after arming. However, if Auto Bypass is programmed, the keypad will beep upon arming (does not apply to selective- or
LNAPCO Security Systems | X |