Zone will go into an instant alarm. If the panel is armed with the entry delays canceled (Instant protection), any violation on the Exit/ Entry Zone or the Exit/Entry Follower Zone will cause an immediate alarm.
Exit Time Restart
This option allows for the following scenario prior to the end of the Exit Time: a violation of an entry/exit zone, a restore, and a sec- ond violation of an entry/exit zone restarts the Exit Time. The panel does not allow the Exit Time to be restarted more than once. The default setting for this option is enabled.
Expansion Module Zones; EZM Type; EZM Tamper See Tamper
Zones
Each
Regardless of how the modules are arranged, the expansion zones are divided into
EZ Arming (Easy Arming); Easy Arming Closing Report
Permits quick arming by simply pressing the Dbutton for "Classic" RP Style keypads. Each keypad may be individually
programmed for Easy Arming (see Keypad Features). Disarming still requires entry of a valid user code. NOTE: Do not program in UL installations. If closings are reported, Easy Arming will report as User 67. Press and hold Por Qto EZ Arm "K Se-
ries" keypads.
EZ Zone Doubling
The control panel zone configuration may be expanded from 8 to 16 zones without the use of EZM Modules. To do so simply select "Zone Doubling" and connect zones as shown in Wiring Diagram. The 3.9K EOL resistor must be placed at the end of the loop of the higher zone. For proper supervision, the 2.2K EOL resistor must be placed at the end of the loop of the lower zone.
Note: If Zone Doubling is to be used, then normally closed devices must be wired to both zones. If Normally open zones for fire or panic devices are required, then the lower zone (2.2K EOL resistor) must be used and the higher zone (3.9K EOL resistor) must not be programmed for any area.
Fire; Keypad Fire
Any zone may be programmed for Fire. Connect
supplementary to the hardwired zones. Note: This feature shall not be considered a substitute for listed manual initiating devices. A fire condition that has not been restored will cause the zone number and description to scroll. To reset (acknowledge) the condition,
enter a valid code, then press the Ubutton.
Fire Verification (Not for use in California)
An alarm on any Fire Zone programmed for "Fire Verification" and connected to the fire power terminal will cause all fire zones to be powered down for 12 seconds. (All devices must be wired with + power on Terminal 25). After this time, power is restored and a 4- second
GEM-Print
A printer can be made to print all logged operations directly from the panel, when programmed for "Enable
Include Selective Bypass In Conditional Closing/Status See Closing Report.
Glossary