Glossary
Page 28 |
| WI1424A 1/06 | |
|
|
|
|
| OUTPUT | WIRING | REMARKS |
| Alarm Output (Burg.) | 3(+) & | Single Bell Output; program Alarm Output for Burg. See System Options in the Programming Instructions WI1422 and WI1423. |
| Pulse Alarm Output | 3(+) & | Single Bell Output; program Pulsed Output for Fire. See System Options in the Programming Instructions WI1422 and WI1423. |
| (Pulsed) |
|
|
| PGM1 Output | 5(+) & | Programmable Output. See System Options in the Programming Instructions WI1422 and WI1423. |
| PGM2 Output | 5(+) & | Programmable Output. See System Options in the Programming Instructions WI1422 and WI1423. |
Alarm Outputs
In UL installations, (1) see Time Selection for timeout requirements; (2) Fire zones must be programmed for PulseAlarm Output, and the option "Change Pulse Alarm to Cadenced Alarm" must be programmed. Note: For PGM1 and PGM2 are Lug
Alarm; Alarm Restore Telco 1/Telco 3 See Report Telco 1/Telco 3
Alarm; Alarm Restore Telco 2 See Backup Report on Telco 2
Alarm Supervisory
An Alarm Supervisory indicates that there is an open in the circuit to the Alarm (Bell) Output and requires immediate attention. A 2.2K EOL resistor is required. See wiring diagram.
Ambush (Keypad Ambush); Ambush Codes; Enable Global Ambush
There are two types of Ambush Codes: (1) A
Ambush Type 1: (a
Ambush Type 2: (a separate and unique user code), this type must be used in a SIA
Be sure to inform the user what their Ambush Code is, and that the Arm/Disarm Code must be entered less than 10 seconds after the Ambush Code for an ambush report to be sent. When "ENABLE GLOBAL AMBUSH" is selected and no Ambush code has been entered and the keypads have been selected for AMBUSH, then the AMBUSH CODE will default to "99".
Answering Machine Pickup Without Line Seizure See
Anti-Jam Communicator Time
If the communicator does not detect a dial tone within 12 seconds, the
Areas; Zone Area
Although the default program will automatically set up Zones 1 through 8 for Zone Area 1, the panel may be partitioned into two areas. Every zone must be assigned to at least one area to be used. At least one zone must be assigned to Area 1. If a zone is selected for both areas, that common zone will not arm until both areas are armed. If any area disarms, the common zone will disarm.
Keypad Area Assignments
Silencing Alarm Area (determines which alarms an area may silence); Subscriber Opening/Closing ID Numbers and Event ID Numbers (if reporting); System Trouble Subscriber ID Number
If "Priority Area Arming" is selected, the Priority Area must be armed before the Arming Area can be armed.
time (such as: 00:02 representing 2 minutes), and a