Chapter 2 Using Your 653X
© National Instruments Corporation 2-19 653X User Manual
For example, if you specify a timebase of 100kHz and a timebase divisor 
of 25, the resulting acquisition/generation rate would be 4 kHz. 
100kHz/25 = 4 kHz.
Note If you are using a version of NI-DAQ prior to version 6.8, the minimum value for 
timebase divisor is 2.
Note In LabVIEW, you can specify the transfer rate directly using the DigitalClock 
ConfigVI (called by the DIO Start VI). The software will choose the closest transfer rate 
by selecting the frequency and divisor. To see the actual transfer rate, create an indicator at 
the actual clock frequency output of the Digital Clock Config VI.
Deciding How to Start and Stop Data Transfer—TriggeringBy default, data transfer starts upon a software command (the Digital 
Buffer ControlVI called by th e DIOS tart VI in LabVIEW and the 
DIG_Block_In and DIG_Block_Out functions in NI-DAQ C interface). 
However, you have the option of using a hardware trigger to start, stop, or 
start and stop data transfer.
The three types of trigger signals available are the start trigger, the stop 
trigger, or the start and stop trigger.
Start Trigger
A start trigger is a trigger that initiates a pattern I/O upon receipt of a 
hardware trigger on the ACK (STARTTRIG) pin.
Figure 2-8.  Starting Data Transfer Using a Trigger
Stop Trigger
When using a stop trigger, transfer starts upon a software command. Once 
a hardware trigger is received on the STOPTRIG pin, a predetermined 
amount of pretrigger and posttrigger data is saved in the buffer. Once this 
REQ
ACK (STARTTRIG)
Posttrigger Data