Chapter 3 Timing Diagrams
653X User Manual 3-40 ni.com
Figure 3-37. Long Pulse Output Timing Diagram
Note With REQ edge latching disabled (default), output data valid will hold trdo ns after
the REQ edge with REQ edge latching enabled, that data will be held for at most trdo ns
after the REQ edge deasserts.
Parameter Description Minimum Maximum
Input Parameters
trr* REQ pulse width 75 —
tr*r REQ inactive duration 75 —
tar ACK to next REQ 0—
Output Parameters
taa* ACK pulse width 1251—
tr*do REQ inactive to new output data
(with REQ-edge latching)
050
trdo REQ to new output data
(with REQ-edge latching disabled)
0—
tdoa Output data valid to ACK
(with REQ-edge latching disabled)
25 —
1 taa* (min.) = 125 + programmable delay
REQ
Output Data Valid
(REQ-edge
latching)
Output Data Valid
(REQ-edge
latching disabled)
tr*r
tr*do
tdoa
tar
taa*
trr*
ACK
trdo
ACK and REQ are shown as active high