Chapter 2 Using Your 653X
© National Instruments Corporation 2-27 653X User Manual
Deciding Which Lines You Want to MonitorYou need to specify which of the lines in your acquisition you want to 
monitor for changes.
Specify which bits are significant to you by using a software line mask in 
the DIG_Trigger_Config function in NI-DAQ C interface, and the 
Digital Trigger Config VI for LabVIEW. In the following example, the user 
specifies the mask to detect changes on the two least-significant bits of a 
port. Pattern 1 does not have changes in the two bits of interest and data is 
not latched, but for pattern 2, a change is detected on one of the two bits of 
interest, and the value of the entire port is acquired.
Figure 2-15.  Change Detection Example Settings
Deciding How to Start and Stop Data Transfer—TriggeringBy default, data transfer starts upon a software command (the 
Digital Buffer Control VI called by the DIO Start VI in LabVIEW and the 
DIG_Block_In and DIG_Block_Out functions in NI-DAQ C interface). 
However, you have the option of using a hardware trigger to start, stop, or 
start and stop data transfer.
16 bits Port 0, Port 1 Group 1
Port 2, Port 3 Group 2
32 bits Port 0, Port 1, Port 2, Port 3 Group 1
Mask 00000011
Initial Input 
Patter n
00000010
Input Pattern 1 01000010 No change on specified 
bits. 
Data is not latched.
Input Pattern 2 00000011 Change detected, 
latch entire port.
Table 2-4.  Port and Timing Controller Combinations (Continued)
Transfer 
Width
Possible Port 
Combinations
Timing Controllers 
ThatC an Be Used