© National Instruments Corporation 2-23 653X User Manual
Monitoring Data Transfer
To monitor your data transfer once data transfer starts:
NI-DAQ C interfaceCall DIG_Block_Check to monitor finite data
transfer. Forcontinuous transfers, use Get_DAQ_Device_Info to
obtain the cumulative transfer count (DIG_Block_Check does not
return the number of buffer iterations completed). The following table
lists the attribute types and values returned for
Get_DAQ_Device_Info:
Note You should always read the least significant bits of the transfer count before reading
the most significant bits. The 32 most significant bits of the transfer count is cached in
software when you read the least significant bits.
LabVIEWUse the Digital Buffer Write VI or the Digital Buffer
Read VI, which are called by the DIO Read VI, the DIO Write VI, and
the DIOWait VI.
Connecting Signals
Connect digital input signals to the I/O connector using the pinout
diagrams, Figures C-1, 653X I/O Connector 68-Pin Assignments, or C-2,
68-to-50-Pin Adapter Pin Assignments.
If you are using an external source for your REQ signal, connect it to the
appropriate REQ pin of the I/O connector.
Transfer
Direction Attribute Value Returned
Input ND_READ_MARK_H_SNAPSHOT_GR1 Most significant 32-bit of transfer count
ND_READ_MARK_H_SNAPSHOT_GR1
ND_READ_MARK_L_SNAPSHOT_GR1 Least significant 32-bit of transfer count
ND_READ_MARK_L_SNAPSHOT_GR2
Output ND_WRITE_MARK_H_SNAPSHOT_GR1 Most significant 32-bit of transfer count
ND_WRITE_MARK_H_SNAPSHOT_GR2
ND_WRITE_MARK_L_SNAPSHOT_GR1 Least significant 32-bit of transfer count
ND_WRITE_MARK_L_SNAPSHOT_GR2