©NationalInstruments Corporation 3-9 653XUser Manual
Figure 3-6. BurstOutput Timing Diagram (Default)
Parameter Description Minimum Maximum
InputParameters
tpc PCLK cycletime 50 —
tpw PCLK high pulse duration 20 —
tpl PCLK lowpulse duration 20 —
trs Setup time from REQ validto PCLK
fallinge dge
1—
trh Holdt ime from PCLK to REQ invalid 0 —
Output Parameters
tpa PCLK to ACKvalid — 22
tah Hold time from PCLK to ACKinvalid 3 —
tpdo PCLK to output data valid — 28
tdoh Hold time from PCLK to output data
invalid
5—
Alltiming values are in nanoseconds.
PCLK
ACK
DataOut Valid
REQ
t
rs
t
pa
t
pdo
t
pw
t
pl
t
pc
t
rh
t
ah
t
doh