Chapter3 TimingDiagrams
653XUser Manual 3-34 ni.com
Figure3-31. LeadingEdge Output Timing Diagram
Note WithREQ edge latching disabled (default), output data valid will hold trdo ns after
the REQ edge occurs. WithREQ edge latching enabled , that data will be held for at most
trdo ns after the REQ edge deasserts.
Parameter Description Minimum Maximum
InputParameters
trr* REQ pulse width 75 —
tr*r REQ inactiveduration 75 —
tar ACK to next R EQ 0 —
Output Parameters
taa* ACKpulse width 125 —
tr*a* REQi nactiveto ACK inactive 150 —
tr*do REQ inactiveto new output data
(with REQ-edge latching)
050
trdo REQto new output data
(withREQ-edge latching disabled)
0—
tdoa Output data validt o ACK
(withREQ-edge latching disabled)
251—
1tdoa(min.) = 25 + programmable delay
REQ
OutputData Valid
(REQ-edge
latching)
OutputData Valid
(REQ-edge
latchingdisabled)
tr*r
tr*a*
tr*do
tdoa
tar
taa*
trr*
ACK
trdo
ACKand REQ are shown as active high