NCR 7883 manual Electrical Wiring, Installation Type Input Voltage L1, L2 Circuit Breakers

Models: 7883

1 75
Download 75 pages 6.41 Kb
Page 38
Image 38

NCR RealScan 7883 Installation and Owner Guide

Electrical Wiring

Input

Voltage

Neutral and Ground Bus

L3

Main Service

Panel

 

Belt Control

Belt

G N

Lighting

Motor

Misc. Equip.

Conduit

Circuit A: Checkstand

Checkstand

Frame

Note: The electrical wiring must meet all electrical codes, laws, and regulations.

Feeder wiring and insulated ground from main service panel to distribution panel to be run in metal conduit.

Isolated/Insulated

Circuit Breakers

 

Ground Bus

NCR circuits should be run in

 

separate metal Conduits.

 

Note: NCR circuits must be dedicated to

L1

NCR equipment or other logically

connected electronic equipment

 

 

(modems, DAA, bridges, etc.)

 

Circuit B: Terminal

L2

 

Neutral

Circuit C: Scanner

Receptacle should be easily

Bus

accessible and near the scanner

Distribution Panel

 

 

Isolated Ground Receptacles

Installation Type

Input Voltage

L1, L2

Circuit Breakers

U.S., Canada, &

100Vac to 120Vac

100Vac to 120Vac

Standard single-pole; value

Japan

 

 

determined by type of device

 

 

 

International

220Vac to 240Vac

220Vac to 240Vac

branch and by electrical code.

 

 

 

 

European

220Vac

220Vac

European double-pole.

20254

38 of 75

04/04

497-0424789 Release F

Page 38