NCR RealScan 7883 Installation and Owner Guide

Electrical Wiring

Input

Voltage

Neutral and Ground Bus

L3

Main Service

Panel

 

Belt Control

Belt

G N

Lighting

Motor

Misc. Equip.

Conduit

Circuit A: Checkstand

Checkstand

Frame

Note: The electrical wiring must meet all electrical codes, laws, and regulations.

Feeder wiring and insulated ground from main service panel to distribution panel to be run in metal conduit.

Isolated/Insulated

Circuit Breakers

 

Ground Bus

NCR circuits should be run in

 

separate metal Conduits.

 

Note: NCR circuits must be dedicated to

L1

NCR equipment or other logically

connected electronic equipment

 

 

(modems, DAA, bridges, etc.)

 

Circuit B: Terminal

L2

 

Neutral

Circuit C: Scanner

Receptacle should be easily

Bus

accessible and near the scanner

Distribution Panel

 

 

Isolated Ground Receptacles

Installation Type

Input Voltage

L1, L2

Circuit Breakers

U.S., Canada, &

100Vac to 120Vac

100Vac to 120Vac

Standard single-pole; value

Japan

 

 

determined by type of device

 

 

 

International

220Vac to 240Vac

220Vac to 240Vac

branch and by electrical code.

 

 

 

 

European

220Vac

220Vac

European double-pole.

20254

38 of 75

04/04

497-0424789 Release F

Page 38
Image 38
NCR 7883 manual Electrical Wiring, Installation Type Input Voltage L1, L2 Circuit Breakers