NCR RealScan 7883 Installation and Owner Guide
Electrical Wiring
Input
Voltage
Neutral and Ground Bus
L3
Main Service
Panel
| Belt Control | Belt | |
G N | Lighting | ||
Motor | |||
Misc. Equip. |
Conduit
Circuit A: Checkstand
Checkstand
Frame
Note: The electrical wiring must meet all electrical codes, laws, and regulations.
Feeder wiring and insulated ground from main service panel to distribution panel to be run in metal conduit.
Isolated/Insulated | Circuit Breakers | |
| ||
Ground Bus | NCR circuits should be run in | |
| separate metal Conduits. | |
| Note: NCR circuits must be dedicated to | |
L1 | NCR equipment or other logically | |
connected electronic equipment | ||
| ||
| (modems, DAA, bridges, etc.) | |
| Circuit B: Terminal | |
L2 |
| |
Neutral | Circuit C: Scanner | |
Receptacle should be easily | ||
Bus | accessible and near the scanner | |
Distribution Panel |
| |
| Isolated Ground Receptacles |
Installation Type | Input Voltage | L1, L2 | Circuit Breakers | |
U.S., Canada, & | 100Vac to 120Vac | 100Vac to 120Vac | Standard | |
Japan | ||||
|
| determined by type of device | ||
|
|
| ||
International | 220Vac to 240Vac | 220Vac to 240Vac | branch and by electrical code. | |
|
|
|
| |
European | 220Vac | 220Vac | European |