NCR 7883 manual Calibrating the Mettler Toledo Scale

Models: 7883

1 75
Download 75 pages 6.41 Kb
Page 47
Image 47

NCR RealScan 7883 Installation and Owner Guide

Calibrating the METTLER TOLEDO® Scale

Before proceeding make sure the scanner is configured for a scale. The programming tag sequence below. If speech is enabled, the 7883-1200 will speak that the Scale Failed if the scale is not connected or not calibrated and the scanner is configured for a scale. The scanner may also have to be set for the proper weight. Data sent by the 7883 will contain 4 digits for weight in pounds and 5 digits for weight in kilograms; these sequences are also provided below.

Programming Mode, Hex 3, Hex 0, Hex 3, Save and Reset.

Programming Mode, Hex 3, Hex 0, Hex 1, Save and Reset. (kilograms)

Programming Mode, Hex 3, Hex 0, Hex 2, Save and Reset. (pounds)

1.Use a screw driver or car key to pry up the Top Plate until you can get hold of it, then lift if off the unit.

20220

2.Remove the Calibration Switch cover screw.

Calibration Switch

Cover Screw

20221

3.Press the Calibration Button. One short beep per second starts to sound.

4.Place the Top Plate on the scale. Do not put anything on the Top Plate. It is highly recommended to use the scale display as it has a scale zero switch and prompts for proper weight.

497-0424789 Release F

04/04

47 of 75

Page 47
Image 47
NCR 7883 manual Calibrating the Mettler Toledo Scale