NCR RealScan 7883 Installation and Owner Guide

5.Depress the Zero Scale button or scan the Reset Scale tag. Two short beeps per second start to sound.

6.Place 20 pounds (or 10kg) on the Top Plate.

7.Depress the Zero Scale button or scan the Reset Scale tag. One long beep per second starts to sound.

8.Remove the 20 pounds (or 10 kg) from the Top Plate.

9.Depress the Zero Scale button or scan the Reset Scale tag. All beeps stop.

10.Replace the Calibration Switch Cover Screw.

11.Scan the Reset Scale tag.

Note: If using the Reset tag, the scanner speaks (assuming speech is enabled) after completing reset. You must have Firmware above 497-0434118 to use Scale Reset tag for calibrating the scale; as noted above, it is recommended the scale display be used.

48 of 75

04/04

497-0424789 Release F

Page 48
Image 48
NCR manual NCR RealScan 7883 Installation and Owner Guide