(2)When using CN connector on DAIA Card

Connect the cable to a CSU or directly to the Remote PIM via the CN connector on the DAIA/DAIC card as shown in Figure 3-39.Connection of DAIC cards between the Main PIM and the Remote PIM is available in the same manner as the DAIA-DIAB connection.

BWB

MAIN PIM

DAIA/

CN

DAIC

 

TWISTED-PAIR CABLE (SHIELD TYPE)

MDF

CSU

 

 

Note 1

 

MAX.656 ft. (200 m)

 

 

 

(0.65Φ cable)

 

DAIA/DAIC

MDF

 

 

CN

 

 

 

 

 

SEND

 

 

 

 

 

 

 

 

 

 

 

BA1

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

TB

 

 

 

 

 

 

 

 

 

 

 

AA1

3

 

 

 

 

 

 

 

TA

 

TO CSU/REMOTE PIM

 

BA0

2

 

 

 

 

 

 

 

RB

 

 

 

 

 

 

 

 

 

 

 

 

AA0

1

 

 

 

 

 

 

 

RA

 

 

 

 

 

 

 

 

 

 

 

 

RECEIVE

 

 

 

 

 

 

 

 

 

 

 

CN CONNECTOR

 

 

 

 

 

 

 

 

 

TB

TA

RB

RA

Note 1: When the Remote PIM is directly connected without CSU, maximum distance is 1312 ft. (400 m) between the Main PIM and the Remote PIM.

Note 2: When the DAIA card is mounted in the MP/FP slot, be sure to connect the cable to the CN con- nector on the DAIA card.

 

Figure 3-39 DTI Cable Connection via CN Connector (Main Site)

CHAPTER 3

ND-46550 (E)

Page 64

 

Revision 2.0

 

Page 72
Image 72
NEC 151944 system manual DTI Cable Connection via CN Connector Main Site