CHAPTER 3 ND-46550 (E)

Page 64

Revision 2.0
(2) When using CN connector on DAIA CardConnect the cable to a CSU or directly to the Remote PIM via the CN connector on the DAIA/DAIC card asshown in Figure 3-39. Connection of DAIC cards between the Main PIM and the Remote PIM is a va il able inthe same manner as the DAIA-DIAB connection.

Figure 3-39 DTI Cable Connection via CN Connector (M ain Site)

CSU
MDF
TWISTED-PAIR
CABLE
DAIA
BWB MAIN PIM
(SHIELD TYPE)
CN
DAIA/DAIC MDF
CN
TB
TA
RB
RA
TO CSU/REMOTE PIM
SEND
RECEIVE
4
3
2
1
BA1
AA1
BA0
AA0
TB
TA
RB
RA
CN CONNECTOR
(0.65Φ cable)

Note 1: When the Remote PIM is directly connected without CSU, maximum distance is 1312 ft. (400 m)

between the Main PIM and the Remote PIM.

Note 2: When the DAIA card is mounted in the MP/FP slot, be sure to connect the cable to the CN con-

nector on the DAIA card.
Note 1
MAX.656 ft. (200 m)

/

DAIC