5.SYSTEM CAPACITY

Table 2-3shows the system capacity.

Table 2-3 System Capacity

 

 

CAPACITY

 

 

 

 

 

 

 

 

 

 

MAIN PIM

REMOTE PIM

 

 

DESCRIPTION

 

 

 

 

REMARKS

 

SMALL

1000 IVS

 

 

 

 

 

 

2000 IVS

PLATFORM

 

 

 

(48 Port)

 

 

 

 

(72 Port)

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. number of DAIA card

3

-

-

 

 

 

 

 

 

 

 

Max. number of DAIB card

-

1

1

 

 

 

 

 

 

 

 

Max. number of DAIC card

6

2

1

 

 

 

 

 

 

 

 

Max. number of ports on

-

24

24

Main PIM

:DAIA

Remote Site

 

Note 1

Note 1

Remote PIM :DAIB

 

 

 

 

 

 

 

 

48

48

Main PIM

:1 DAIA, 2 DAIC

 

 

Note 1

Note 1

Remote PIM :1 DAIB, 2 DAIC

 

 

 

 

 

 

 

 

64

-

Main PIM

:1 DAIA, 2 DAIC

 

 

Note 1

Remote PIM :1 DAIB, 2 DAIC

 

 

 

 

 

 

 

 

Number of PIM

 

 

 

Number of PIM depends on the

 

1, 2

3

3

number of Main PIM and

 

Note 2

 

Remote PIM. (Refer to Chapter,

 

 

 

 

 

 

 

Section 2.)

 

 

 

 

 

 

 

3, 4

2

2

 

 

 

Note 2

Note 2

 

 

 

 

 

 

 

 

 

 

 

 

 

5, 6

1

1

 

 

 

 

Note 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7, 8

0

0

 

 

 

Note 3

Note 3

 

 

 

 

 

 

 

 

 

 

 

 

Note 1: 1 port is used for the control signaling channel.

Note 2: This number refers to the maximum number of remote offices. The remote office can have only one re- mote PIM.

Note 3: When the main site consists of 7 or 8 PIMs, a Remote PIM cannot be provided.

CHAPTER 2

ND-46550 (E)

Page 8

Revision 2.0

Page 16
Image 16
NEC 151944 system manual System Capacity, Daia, DAIA, 2 Daic