Table 3-5 Switch Settings on PN-DAIC Card (Continued)
SWITCH NAME | SWITCH | SETTING | FUNCTION | CHECK | |
NUMBER | POSITION | ||||
|
|
|
| SW3 (Dip SW) | 1 | ON | Set the equalizer according to the cable | |||||||
|
|
|
|
|
| length between the system and the CSU. | |||||
ON |
|
|
| OFF | |||||||
|
|
|
|
|
|
|
|
| |||
1 2 3 4 |
|
|
|
| CABLE LENGTH |
| |||||
|
|
|
|
|
|
| |||||
|
| 2 | ON |
| |||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| ON | ON | ON | 0 - 131.2 ft (0 - 40 m) |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ON | ON | OFF | 131.2 - 262.5 ft. (40 - 80 m) |
|
|
|
|
|
| OFF |
| |||||
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| ON | OFF | ON | 262.5 - 394 ft. (80 - 120 m) |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ON | OFF | OFF | 394 - 525 ft. (120 - 160 m) |
|
|
|
|
| 3 | ON |
| |||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| OFF | ON | ON | 525 - 656 ft. (160 - 200 m) |
| ||
|
|
|
|
|
|
| OFF | OFF | OFF | Signal is not sent |
|
|
|
|
|
| OFF |
| |||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 4 | ON | When mounting this card on remote | |||||
|
|
|
|
|
| site. |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| OFF | When mounting this card on main site. |
In Table
figure and , the setting of the switch varies with the system concerned.
Note: When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card.
Page 27
Revision 2.0