ND-46550 (E) CHAPTER 3

Page 29

Revision 2.0
2.1.5 BUS Cable Connection(1) Cable connection between BUS Card and the DAIA CardConnect the DAIA card to the BUS card by the RMT PCM-0.3 CA and 17-TW-0.3 CONN CA-A, as shown inFigure 3-9.

Note: Up to three DAIA cards can be connected dir ectly by a daisy chain connection on one PIM. If two or thr e e

DAIA cards are mounted on one PIM, the 17-TW-0.3 CONN CA-A is required. When the system is morethan one PIM configuration, the DAIA cards must be mounted on the first/last PIM due to the number ofconnectors of a BUS card.

Figure 3-9 BUS-DAIA Cable Connection

(1) 1-PIM Configuratio n
BS00
DAIA
BS00
DAIA
DAIA
BS00
DAIA
DAIA
: RMT PCM-0.3 CA
: 17-TW-0.3 CONN CA-A
DAIA BUS
DAIA BUSDAIA
DAIA BUSDAIA
DAIA
When m ounting 1 DAIA card
When m ounting 2 DAIA cards
PCM1
PCM0
CN2
CN1
CN2
CN1
PCM1
PCM0
PCM1
PCM0
When m ounting 3 DAIA cards
PCM1
PCM0
PCM1
PCM0
CN2
CN1
PCM1
PCM0
CN1
CN2
PIM0
PIM0
PIM0
DAIA