CHAPTER 3 ND-46550 (E)
Page 48
Revision 2.0
2.2.7 Mounting of Line/Trunk Card on 1000 IVS PIM
Mount the Line/Trunk cards in the following slots on the Remote PIM. Connect the line cables referring to Figure
3-24 through Figure 3-26 and Table 3-9.
Figure 3-24 Mounting Location of Line/Trunk Card (1000 IVS)
Table 3-9 LTC Connector Accommodation (1000 IVS)
REMOTE PIM TYPE LTC CONNECTOR CARD SLOT NUMBER
1000 IVS
(48 Port PIM) LTC0 LT01~LT03
LTC1 LT04~LT08, LT00
LTC1
LTC0
BWB
FRONT
P
W
R
LT01
LT02
LT03
LT04
LT05
LT06
LT07
LT08
*1 When providing DA IB card only (Max. 23 po rts): LT01~LT03slot
*2 Wh en providing one DAIB card and on e DAIC card (Max. 4 ports): LT00 ~LT08 slot (Mounted DAIB in MP, mountedDAIC in LT07 so LT
08 is available for 8 ports ca rd)
*3 When DAIC is mounted in slot 07, slot 06 must use the 4-port Line/Trunk card, so that the last 4 ports of slot 06 do not interfere with the
DAIC card and when DK00 ca n assign on this last 4-por ts, the system can have a Ma x. of 44 ports.
*1
*2
Remote PIM
LINE/TRUNK
CARD
LT00
Note 1: The CSI card can not be used on the Remote PIM.
Note 2: One port of the last 24 ports can not be used for li ne/trunk , be cause it i s use d for c ontrol
signaling channel.