NDA-24318 CHAPTER 2
Page 13
Issue 1
CIRCUIT CARD EXPLANATIONS
SW20
1~6
Designation of Flexible PAD Value Note 1
7ON Fixed to OFF.
OFF ×
8ON Fixed to OFF.
OFF ×
Table 2-2 Switch Setting Meanings (Continued)
SWITCH
NAME SWITCH
NUMBER SETTING STANDARD
SETTING MEANING
SW20
-1 SW20
-2 SW20
-3 SW20
-4 SW20
-5 SW20
-6 PAD
VALUE
OFF OFF OFF OFF OFF OFF 16 [dB]
ON OFF OFF OFF OFF OFF 15 [dB]
OFF ON OFF OFF OFF OFF 14 [dB]
ON ON OFF OFF OFF OFF 13 [dB]
OFF OFF ON OFF OFF OFF 12 [dB]
ON OFF ON OFF OFF OFF 11 [dB]
OFF ON ON OFF OFF OFF 10 [dB]
ON ON ON OFF OFF OFF 9 [dB]
OFF OFF OFF ON OFF OFF 8 [dB]
ON OFF OFF ON OFF OFF 7 [dB]
OFF ON OFF ON OFF OFF 6 [dB]
ON ON OFF ON OFF OFF 5 [dB]
OFF OFF ON ON OFF OFF 4 [dB]
ON OFF ON ON OFF OFF 3 [dB]
OFF ON ON ON OFF OFF 2 [dB]
ON ON ON ON OFF OFF 1 [dB]
OFF OFF OFF OFF ON OFF 0 [dB]