NDA-24318 CHAPTER 4
Page 47
Issue 1
OPERATION TESTS AFTER INSTALLATION
CHAPTER 4 OPERATION TESTS AFTER INSTALLATION
1. GENERAL
This chapter explains the procedure to verify the normal operation of the IPTRK circuit
card, when installation and necessary data setting have been completed. This chapter also
explains the procedures to test and correct possible IPTRK circuit card-related faults.
2. CCIS NETWORKING VIA IP [C-163]/VOICE OVER IP (H.323)
When using the H.323 Handler (PA-8IPTB-A) as a signaling interface for Voice over IP (H.323), perform the
following circuit card operation tests. If necessary, perform fault repairs.
Caution:Some LSIs on this circuit card may be hot. Handle with care.
1. Test of OPE lamp on IPTRK circuit card: Note
Note: H.323 Handler (PA-8IPTB-A).
a.) See if the OPE lamp on the IPTRK circuit card Note is lighting green. This lamp lights if the
circuit card is operating normally.
Note: H.323 Handler (PA-8IPTB-A).
b.) When the OPE lamp is OFF, initialize the circuit card, or perform the insertion/extraction of the
circuit card once or twice. If the lamp still do es not light, replace the circuit card.
Figure 4-1 Lamps to be Tested (CCIS Networking via IP [C-163])
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
SUBOPE3
SUBOPE2
BUSY
L3
L2
L1
IP-TXRX
IP-100M
F-TXRX
F-100M
F-LRR
F-LINK
F-COL
MODE
IPCON
FCON
MB
MBR
Not Used
Not Used
Not Used Not Used
OPE
Is IPTRK card
IP-LRR
Is IP network available
for connection?
IP-LINK
Is IPTRK-IP network link
physically established?
SUBOPE1
Is appropriate data
assigned on GK?
IP-COL
IPTRK Circuit Card (H.323 Handler/
(H.323 Handler)
operating normally?
PA-8IPTB-A)