OPERATION TESTS AFTER INSTALLATION
1. Test of IP-LINK lamp on IPTRK circuit card: Note
Note: H.323 Handler (PA-8IPTB-A).
a.) See if the IP-LINK lamp on the IPTRK circuit card Note is lighting green.
This lamp will light if the circuit car d is physically connected to the IP
network.
Note: H.323 Handler (PA-8IPTB-A).
b.) When the IP-LINK lamp is OFF, make sure that the Ethernet cable is securely
connected to the IPCON connector. Make sure that neither the Ethernet cable nor the router are
faulty. If necessary, replace the Ethernet cable.
2. Test of SUBOPE1 lamp on IPTRK circuit card Note:
Note: H.323 Handler (PA-8IPTB-A).
a.) See if the SUBOPE1 lamp on the IPTRK circuit card Note is lighting green. This lamp will light
when the appropriate data has been assigned on the Gate Keeper (GK) side.
Note: H.323 Handler (PA-8IPTB-A).
b.) When the SUBOPE1 lamp is OFF, make sure that the relate d office d ata is corr ectly ass igned on
both the PBX side and the Gate Keeper (GK) side.
3. Test of IP-LRR lamp on IPTRK circuit card: Note
Note: H.323 Handler (PA-8IPTB-A).
a.) See if the IP-LRR lamp on the IPTRK circuit card Note is lighting green. This lamp will light if
the IP network is available for connection establishment.
Note: H.323 Handler (PA-8IPTB-A).
b.) When the IP-LRR lamp is OFF, make sure that the related office data was correctly assigned.
Make sure that each IP address assigned on the AGIP command is correct.
4. Test of Speech Conditions with Distant Node:
a.) Perform the connection test to see if speech can be made with the counterparts of the connected
node.
b.) If any test result is abnormal, make sure that the related office data was assigned correctly.
5. Test of System Messages:
a.) When an IPTRK circuit card Note is installed, the following messages may be created:
Note: H.323 Handler (PA-8IPTB-A).
For CCIS Networking via IP [C-163]:
33-R IP CARD WARNING
33-S IP CARD FAILURE
33-T IP CARD RECOVERY
33-U H.323 INFORMATION NOTICE
b.) When any of the messages above are created, make sure that the Ethernet cable is securely
connected to the IPCON connector (on the IPTRK circuit card), or perform the continuity test of
the cable (voltage and resistance measurement), using a voltmeter. Otherwise, replace the IPTRK
circuit card or H.323 Handler.