NDA-24318 CHAPTER 3
Page 45
Issue 1
OFFICE DATA PROGRAMMING
This figure represent example data when FCCS routing data is not assigned by using the AFPC
command. Be sure to assign the following dummy data when using this configuration.
Figure 3-18 FCCS Networking via IP [F-36] - FCCS Network via IP Tandem Connection
(AFPC Dummy Data) Example Data Sheet 4
Note: Be sure to assign dummy data.
POWER
Router
NEAX2400 IPX
FPC 2
IPTRK
Tandem Node
C_RT: 150
IP Address: 10.40.222.20
FCHN: 20
POWER
Router IPTRK
C_RT: 151
IP Address: 10.40.222.21
FCHN: 21
Use different FCHN for passing through the node
Intranet
NEAX2400 IPX
FPC 1
POWER
Router
NEAX2400 IPX
FPC 3
POWER
Router IPTRK
IPTRK
C_RT: 100
IP Address: 10.40.221.20
FCHN: 10
C_RT: 200
IP Address: 10.40.223.20
FCHN: 30
Example Routing Information Assignment by AFPC and AETH:
AFPC:
FPC 1: None
FPC 2: FPC=1, FCCH=1, P_ROUTE=1, C_RT=150, FCHN=20 Note
FPC=3, FCCH=1, P_ROUTE=1, C_RT=151, FCHN=21 Note
FPC 3: None
AETH:
FPC 1: FPC=2, FCHN=10, C_RT=100, DST_IP=10.40.222.20, NEXT_IP=10.40.222.20
FPC=3, FCHN=10, C_RT=100, DST_IP=10.40.222.20, NEXT_IP=10.40.222.20
FPC 2: FPC=1, FCHN=20, C_RT=150, DST_IP=10.40.221.20, NEXT_IP=10.40.221.20
FPC=3, FCHN=21, C_RT=151, DST_IP=10.40.223.20, NEXT_IP=10.40.223.20
FPC 3: FPC=1, FCHN=30, C_RT=200, DST_IP=10.40.222.21, NEXT_IP=10.40.222.21
FPC=2, FCHN=30, C_RT=200, DST_IP=10.40.222.21, NEXT_IP=10.40.222.21