Nilfisk-ALTO 3.4 Misc. Setup submenu, a. Input Select, b. Output Meters, Digital Inputs, PreMute

Models: 3.4

1 41
Download 41 pages 24.36 Kb
Page 27
Image 27
5.4.3 Misc. Setup submenu

5.4.3 Misc. Setup submenu

Misc. Setup

Input Select

 

Output Meters

 

Temperature

 

Wake Up

 

LCD Contrast

Use this submenu to set a series of system options.

M i

s c .

S e t u p

a. Input Select

Used to choose inputs which MAXIDRIVE3.4 should use.

The options include:

Digital Inputs

Analog Inputs

I n p u t S e l e c t

D i g i t a l

I n p u t S e l e c t

A n a l o g

 

AC INPUT 14W

Apparaten skall anslutas till

 

 

 

 

 

 

 

 

 

 

PUSH

PUSH

 

95-240V 50/60Hz

jordat uttag nar den ansluts

 

PUSH

 

 

 

 

 

 

 

 

 

 

 

 

FUSE: 95-120V T500mAL

till ett natverk

PUSH

 

 

 

 

 

OUTPUTS

 

 

 

 

 

 

 

210-240V T315mAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWR

 

 

 

 

 

 

 

 

 

 

 

 

NEW

TIDE

NEW

TIDE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

NEW

TIDE

 

NEW

TIDE

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

3

 

 

 

 

 

 

 

2

1

2

1

 

 

 

2

1

 

2

1

 

 

 

 

 

 

 

 

3

 

3

A102

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIGITAL IN

RS485 OUT

RS485 IN

RS232

6

5

4

3

2

1

INPUT B

INPUT A

The inputs selected become Input A and Input B.

Any signal on the inputs not selected is ignored.

b. Output Meters

Used to decide whether to display the outputs signal before or after MUTE.

The options include:

PreMute

PostMute

the signal is always shown

the signal is only shown if

no matter what the MUTE status

the output isn't in MUTE

O u t p u t M e t e r s

P r e M u t e

O u t p u t M e t e r s

P o s t M u t e

 

PREV

NEXT

ENTER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLIP

CLIP

 

CLIP

 

CLIP

 

CLIP

 

CLIP

 

CLIP

 

 

 

PRESET

 

 

6

LIMIT

 

LIMIT

 

LIMIT

 

LIMIT

 

LIMIT

 

LIMIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DELAY

 

ESC

12

6

 

6

 

6

 

6

 

6

 

6

 

MAXIDRIVE3.4

 

 

 

18

12

OUTPUT

12

OUTPUT

12

OUTPUT

12

OUTPUT

12

OUTPUT

12

OUTPUT

LTOR

EDIT

 

 

3-WAY STEREO

MODE

UTILITY

 

 

24

24

LEVEL

24

LEVEL

24

LEVEL

24

LEVEL

24

LEVEL

24

LEVEL

DIGITAL CROSSOVER

 

 

 

 

A

B

1

 

2

 

3

 

4

 

5

 

6

 

 

 

 

 

INPUT LEVEL

MUTE

MUTE

MUTE

MUTE

MUTE

MUTE

 

 

 

 

 

 

 

 

 

CARD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26