Olympus zm2000qdk, OM-2 manual Finder Group Units, For most lenses

Models: OM-2 zm2000qdk

1 101
Download 101 pages 40 Kb
Page 60
Image 60

FINDER GROUP UNITS

TYPE

SCREEN

FEATURES

1-1

Microprism-matte

type

(for most lenses)

1-2

Microprism-matte

type

(for standard & telephoto lenses)

1-3

Split image-mane

type

(for most lenses)

1-4

All matte type

(for most lenses)

1-5

Microprism -clear field type

(forwideangle& standard lenses)

1-6

Microprism-clear

field type

(for standard & telephoto lenses)

1-7

Microprism-clear field type (for super

telephoto lenses)

Standard type, suitable for general photography. Fast and accurate

focusing is done on the central microprism spot as well as on the sur- rounding matte area. When a lens with a maximum speed of F5.6 or slower is used, the microprism darkens and focusing must be made on the matte area. The meter needle indicates proper exposures.

Suitable for general photography in conjunction with a standard or telephoto lens. Focusing is done on the microprism spot as well as on the matte area. When a lens with a maximum speed of F8 or slower is used, the microprism spot darkens. The meter needle indicates prop- er exposures.

Suitable for general photography ensuring critical focusing, and ideal

for photographers who prefer the split-field and coincidence type focusing. When a lens with a maximum speed of F5.6 or slower is used, the split prism darkens. The meter needle indicates proper ex- posures.

Suitable for general photography and ideal for photographers who prefer a view field free from microprism or split prism and for those who are accustomed to focus using matte area. Also suitable for super telephoto photography and close-up photography in conjunction with macro lenses and Auto Bellows. The meter needle indicates

proper exposures.

This transparent screen provides an exceptionally bright finder image. Highly suitable for snapshots using wide angle lenses. The lack of matte surface means depth-of-field effects cannot be ascertained. The meter needle does not indicate proper exposures, because its movement varies depending on the lenses used.

This screen provides an extremely bright finder image. Focusing is done on the microprism spot. The lack of matte surface means depth of-field effects cannot be ascertained and the meter needle does not indicate proper exposures.

Developed primarily for use with super telephoto lenses, this clear field screen provides an extremely bright finder image. The micro-

prism spot remains bright even with a lens whose maximum speed is

11.The lack of matte surface means depth-of-field effects cannot be ascertained, the meter needle does not indicate proper exposures.

59

Page 60
Image 60
Olympus zm2000qdk, OM-2 manual Finder Group Units, For most lenses