Omega Engineering OS531, OS530HR, OS53X-CF, OS524, OS533, OS532, OS530L, OS523, OS534 manual Problem

Models: OS523 OS532 OS530HR OS530L OS531 OS533 OS53X-CF OS534 OS524

1 78
Download 78 pages 980 b
Page 55
Image 55

6Troubleshooting Guide

 

Problem

Solution

 

 

 

 

 

The thermometer is

Remove and reinstall the batteries or

 

“locked up” (the

disconnect and reconnect the ac

 

display is “frozen”).

adapter.

 

 

 

 

 

 

 

 

 

The display is either

1. Clean the thermometer lens.

 

erratic or stays at one

Refer to Section 4.2.

 

 

 

 

reading.

 

 

 

 

 

 

 

2. Activate the Diagnostic Program in

 

 

the thermometer as follows:

 

 

a. Pull the trigger and press the

 

 

key to lock the trigger.

 

 

b. Hold down the

key and

 

 

press the

key until

 

 

“VER X.X” is displayed.

You can expect to see and hear the following:

You will see the version number “VER X.X” of the software for about

1second.

You will hear a beep, “TST” is displayed and °F flashes.

Soon after, all of the segments of the display including the backlighting will light up for about

1second.

The display will clear and a PAS (pass) or ERR (error) code may be seen on the display.

6-2

Page 55
Image 55
Omega Engineering OS531, OS530HR, OS53X-CF, OS524, OS533, OS532, OS530L, OS523, OS534 manual Problem