2Using the Handheld Infrared Thermometer

ATC°F

8.Press and hold the key until the Emissivity Display Mode (E) appears.

9.Change the emissivity to the proper value for the target being measured (refer to Section 2.3.1).

10.Aim at the target. The target temperature and emissivity are displayed on the LCD.

11.After all data is taken, press the key to release this mode

NOTE

To disable the Ambient Target Temperature

Compensation at a later time, you must press the

key to get into the Ambient Target Temperature Display Mode. Then press the key to disable it.

NOTE

The target ambient temperature does not change when the thermometer is turned off. However, when the batteries are replaced, it is reset to the default value of 75°F.

2.3.9Sending Temperature Data to a Serial Printer (OS533, OS534, OS523, OS524)

PRN °F

The thermometer can transmit temperature data to a Serial Printer via the RS-232 phone jack and the RS-232 cable.

1.Turn on the Serial Printer and set the following parameters:

Speed:

4800 BPS

One Stop Bit

Data:

8 Bits

No Parity

2.Connect the RS-232 cable between the thermometer and the printer as shown in Figure 2-14.

2-18

Page 33
Image 33
Omega Engineering OS530L, OS530HR, OS531, OS53X-CF, OS524, OS533, OS532, OS523, OS534 manual One Stop Bit