Pacific Research Solutions RI-300e User Manual
Page 74
S-Cmd 44 SCHEDULER TO TRIGGER A MACRO (RI-300 and RI-310 Version 2 Only)
This is a simple scheduler, allowing you to instruct the controller to perform a macro at a certain time of the day. Sixteen
individual schedulers are available. The system time clock must be set properly after each time the power is restored
(S-Command 43) for this command to work correctly. This command can be used to automatically turn on and off the repeater
or the telephone interconnect each day.
SYNTAX: 44 [Scheduler #] [Day] [Time] [Macro start line]
READ BACK: 44 [Scheduler #]
STORAGE: RAM/EEPROM
PARAMETERS: Scheduler # 01-16 = User programmable schedulers
Day 0 = Everyday, 1-Sunday, 2-Monday, 3-Tuesday, 4-Wednesday, 5-Thursday, 6-Friday, 7-Saturday
Time 0000-2359 = Time in Hours and Minutes (24 Hour mode)
Macro start line 000 = Disable scheduler, 001-999 = Macro data memory start line
DEFAULT: All schedulers disabled, macro start line 0.
EXAMPLE: 44 01 0730 0 32 Scheduler #1, Execute macro at start line 32 at 07:30 AM every day.
S-Cmd 44 SCHEDULER TO TRIGGER A MACRO (RI-300e and RI-310e Version 3 Only)
This scheduler requires the real time clock which can only be found in the RI-300e and RI-310e, version 3. This is a full
feature scheduler, allowing you to instruct the controller to perform a macro at a certain time of the day, week, month or year.
Thirty tow individual schedulers are available. This command can be used to automatically turn on and off the repeater or the
telephone interconnect each day or enable a special ID on a given date each year.
SYNTAX: 44 [Scheduler #] [Macro start line] [Week] [Day] [Month] [Time]
READ BACK: 44 [Scheduler #]
STORAGE: RAM/EEPROM
PARAMETERS: Scheduler # 01-32 = User programmable schedulers
Macro start line 000 = Disable scheduler, 001-999 = Macro data memory start line
Week 0 = Ignore day of week field (Everyday),
Week 1 =-Sunday, 2-Monday, 3-Tuesday, 4-Wednesday, 5-Thursday, 6-Friday, 7-Saturday
Day 00-31 = Day of the Month, 00 = Ignore day of month field
Month 00-12 = Month of the Year, 00 = Ignore month of year field
Time 0000-2359 = Time in Hours and Minutes (24 Hour mode)
DEFAULT: All schedulers disabled, macro start line 0.
EXAMPLE: 44 01 032 6 00 00 0730 Scheduler #1, Run macro at start line 32 on Friday at 07:30 AM every week.
44 02 110 0 01 01 0000 Scheduler #2, Run macro at start line 110 on January 1 at 12:00 AM every year.