Pacific Research Solutions RI-300e User Manual Page 154 S-Cmd Command Description and Data Format Read Back Syntax Command Syntax Factory Setting Stored Location
48 Counter trigger
Counter = 1 to 8
Counts = 0 to 255, * = Inc Counter, # = Dec Counter,
0 = Disable or reset counter
Line = Macro starting line number 1 to 999, 0 = disable
48 *
[Counter] 48 [Counter]
[Counts] [Line] All = 0 RAM
EEPROM
50 Squelch level adjust
Adj = 0 to 63 or * up one count, # down one count 50 50 [Adj] 31
RAM
EEPROM
51 Squelch mode
Mode 0 = External Squelch (PI-1),
1 = SmartSqulch, 2 = Normal Squelch
51 51 [Mode] 1
SmartSquel
ch
RAM
EEPROM
52 Squelch set up
Item 1 = Upper threshold, Value = 75 to 200
Item 2 = Lower threshold, Value = 50 to 150
Item 3 = Acquisition time, Value = 0 to 50 in 10 ms inc.
Item 4 = Delay factor, Value 0 to 255
Item 5 = Average factor, Value 0 to 50
Item 6 = Weak signal thres, Value 3 to 50 in 10 ms inc.
52 [Item] 52 [Item] [Value] Upper 160
Lower 130
Aqu 8
Delay 125
Average 25
Weak 5
RAM
EEPROM
53 Telephone Hybrid adjust.
Adj 0 = Auto adjust, 1 ā€“ 64 = Independent settings. 53 53 [Adj] 0
RAM
EEPROM
54 Set Key code (prefix) for macros
Key = 0 to 4 digits N/A 54 [Key] 0
Digits
RAM
EEPROM
55 Set Password for programming, S-Cmd access
PW = 1 to 6 digits 55 55 [PW] 123456
RAM
EEPROM
56 Set Password for telephone incoming ring access
PW = 1 to 6 digits 56 56 [PW] 343
RAM
EEPROM
57 Set Password for telephone incoming control access
PW = 1 to 6 digits 57 57 [PW] 654381
RAM
EEPROM
58 Remote software reset
Controller Serial Number (SN) is 8 digits 58, Read
Software
Version
58 [SN] Serial
Number
N/A
59 Remote EEPROM initialize
Controller Serial Number (SN) is 8 digits N/A 59 [SN] Serial
Number
N/A
60 Reserved
61 Reserved
62 Name user macro commands
Cmd = 000 to 199, Type 0 = Standard, 1 = Telephone,
Type 2 = User S-Cmds, 3 = Wildcard,
Group = 1 to 8, Line = 001 to 999, Name = 1 to 4 digits
62 * [Cmd] 62 [Cmd] [Type]
[Group] [Line]
[Name]
See
Table RAM
EEPROM
63 Macro editor, set start line number pointer
Line = 001 to 999 N/A 63 [Line] N/A N/A
64 Macro editor, insert an S-Command
S-Cmd = 00 to 99 and Data = as req. for S-Cmd
End = ā€œDā€ or no data for last S-Cmd within macro
N/A 64 [S-Cmd]
[Data][End] See
Table
EEPROM
65 If / Than / Else
Var = See Table
Op 0 = Not Equal, 1 = Equal,
2 = Less Than, 3 = More Than
Ref = All values for "Var
65 [Var] [Op]
[Ref] 65 [Var] [Op] [Ref] N/A N/A
66 Read / Write / Push / Pop system data
Action 0 = Read from EEPROM, 1 = Write to EEPROM,
2 = Push to system stack, 3 = Pop from system stack
This command only affects command stored loca t ions
that are in bold & italic.
N/A 66 [Action] N/A N/A
67 Call Macro Line
Line = 1 to 999 (Do not exceed 32 nested calls) N/A 67 [Line] N/A N/A
68 Jump to Macro Line
Line = 1 to 999 N/A 68 [Line] N/A N/A